{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2017-13995 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-13995 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-13995 is a critical authentication bypass vulnerability in iniNet Solutions GmbH SCADA Webserver, published on 4 Oct 2017. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-13995 and fix it if it is affected.\n\nWhat it is: CVE-2017-13995 is a critical authentication bypass vulnerability in iniNet Solutions GmbH SCADA Webserver, published on 4 Oct 2017. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-13995 in the wild and no public exploit code.\n\nAffected product: iniNet Solutions GmbH SCADA Webserver. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-13995/ (Markdown: https://insights.sbomify.com/CVE-2017-13995/index.md)","id":"CVE-2017-13995","markdown":"https://insights.sbomify.com/CVE-2017-13995/index.md","name":"CVE-2017-13995","record":{"aliases":["GHSA-mvv4-fjq9-c9h3"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"SCADA Webserver","requires_auth":"none","summary":"Attackers can bypass authentication to access sensitive HMI pages and modify PLC variables in iniNet Solutions SCADA Webserver.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"ininet_webserver","vendor":"spidercontrol"}],"cvss":{"score":10,"severity":"critical","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-287","name":"Improper Authentication"}],"description":"An Improper Authentication issue was discovered in iniNet Solutions iniNet Webserver, all versions prior to V2.02.0100. The webserver does not properly authenticate users, which may allow a malicious attacker to access sensitive information such as HMI pages or modify PLC variables.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Auth bypass in iniNet Solutions GmbH SCADA Webserver","id":"CVE-2017-13995","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2017"},"n_packages":0,"n_references":2,"next":{"headline":"Path traversal in LOYTEC LVIS-3ME","id":"CVE-2017-13996"},"packages":[],"prev":{"headline":"Cross-site scripting in LOYTEC LVIS-3ME","id":"CVE-2017-13994"},"products":["iniNet Solutions GmbH SCADA Webserver"],"published":"2017-10-04","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"Attackers can bypass authentication to access sensitive HMI pages and modify PLC variables in iniNet Solutions SCADA Webserver.","url":"https://insights.sbomify.com/CVE-2017-13995/"}