{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2017-13999 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-13999 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-13999 is a critical memory corruption vulnerability in WECON Technology Co., Ltd. LeviStudio HMI Editor, published on 17 Oct 2017. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-13999 and fix it if it is affected.\n\nWhat it is: CVE-2017-13999 is a critical memory corruption vulnerability in WECON Technology Co., Ltd. LeviStudio HMI Editor, published on 17 Oct 2017. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-13999 in the wild and no public exploit code.\n\nAffected product: WECON Technology Co., Ltd. LeviStudio HMI Editor. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-13999/ (Markdown: https://insights.sbomify.com/CVE-2017-13999/index.md)","id":"CVE-2017-13999","markdown":"https://insights.sbomify.com/CVE-2017-13999/index.md","name":"CVE-2017-13999","record":{"aliases":["GHSA-4283-grg4-9j23"],"analysis":{"component_type":"desktop_application","fix_type":"upgrade","impacts":["code_execution","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"HMI Editor","requires_auth":"none","summary":"Stack-based buffer overflows in WECON LEVI Studio HMI Editor allow attackers to execute arbitrary code or crash the application via crafted input.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"levi_studio_hmi_editor","vendor":"we-con"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-119","name":"Improper Restriction of Operations within the Bounds of a Memory Buffer"},{"id":"CWE-121","name":"Stack-based Buffer Overflow"}],"description":"A Stack-based Buffer Overflow issue was discovered in WECON LEVI Studio HMI Editor v1.8.1 and prior. Multiple stack-based buffer overflow vulnerabilities have been identified in which the application does not verify string size before copying to memory; the attacker may then be able to crash the application or run arbitrary code.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Memory corruption in WECON Technology Co., Ltd. LeviStudio HMI Editor","id":"CVE-2017-13999","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2017"},"n_packages":0,"n_references":3,"next":{"headline":"Auth bypass in Ctek, Inc. SkyRouter","id":"CVE-2017-14000"},"packages":[],"prev":{"headline":"Information disclosure in LOYTEC LVIS-3ME","id":"CVE-2017-13998"},"products":["WECON Technology Co., Ltd. LeviStudio HMI Editor"],"published":"2017-10-17","related":[{"cvss_score":8.8,"headline":"Memory corruption in Wecon Technologies LEVI Studio HMI Editor","id":"CVE-2017-6035","kev_date_added":null,"published":"2017-04-27"},{"cvss_score":8.8,"headline":"Memory corruption in Wecon Technologies LEVI Studio HMI Editor","id":"CVE-2017-6037","kev_date_added":null,"published":"2017-04-27"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"Stack-based buffer overflows in WECON LEVI Studio HMI Editor allow attackers to execute arbitrary code or crash the application via crafted input.","url":"https://insights.sbomify.com/CVE-2017-13999/"}