{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2017-14014 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-14014 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-14014 is a medium-severity vulnerability in Boston Scientific ZOOM LATITUDE PRM, published on 1 May 2018. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-14014 and fix it if it is affected.\n\nWhat it is: CVE-2017-14014 is a medium-severity vulnerability in Boston Scientific ZOOM LATITUDE PRM, published on 1 May 2018. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-14014 in the wild and no public exploit code.\n\nAffected product: Boston Scientific ZOOM LATITUDE PRM. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-14014/ (Markdown: https://insights.sbomify.com/CVE-2017-14014/index.md)","id":"CVE-2017-14014","markdown":"https://insights.sbomify.com/CVE-2017-14014/index.md","name":"CVE-2017-14014","record":{"aliases":["GHSA-mpfx-7r3v-h2qr"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Medical device","requires_auth":"none","summary":"An attacker with physical access can decrypt protected health information due to a hard-coded cryptographic key in the device.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"zoom_latitude_prm_3120_firmware","vendor":"bostonscientific"}],"cvss":{"score":4.6,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.0"},"cwes":[{"id":"CWE-798","name":"Use of Hard-coded Credentials"},{"id":"CWE-321","name":"Use of Hard-coded Cryptographic Key"}],"description":"Boston Scientific ZOOM LATITUDE PRM Model 3120 uses a hard-coded cryptographic key to encrypt PHI prior to having it transferred to removable media. CVSS v3 base score: 4.6; CVSS vector string: AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hardcoded credentials in ZOOM LATITUDE PRM","id":"CVE-2017-14014","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2017"},"n_packages":0,"n_references":2,"next":{"headline":"Memory corruption in Advantech WebAccess","id":"CVE-2017-14016"},"packages":[],"prev":{"headline":"Auth bypass in ProMinent MultiFLEX M10a Controller","id":"CVE-2017-14013"},"products":["ZOOM LATITUDE PRM"],"published":"2018-05-01","related":[{"cvss_score":4.6,"headline":"Weak cryptography in ZOOM LATITUDE PRM","id":"CVE-2017-14012","kev_date_added":null,"published":"2018-05-01"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-16","vendors":["Boston Scientific"]},"summary":"An attacker with physical access can decrypt protected health information due to a hard-coded cryptographic key in the device.","url":"https://insights.sbomify.com/CVE-2017-14014/"}