{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2017-14017 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-14017 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-14017 is a high-severity vulnerability in Progea Movicon SCADA/HMI, published on 19 Oct 2017. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-14017 and fix it if it is affected.\n\nWhat it is: CVE-2017-14017 is a high-severity vulnerability in Progea Movicon SCADA/HMI, published on 19 Oct 2017. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-14017 in the wild and no public exploit code.\n\nAffected product: Progea Movicon SCADA/HMI. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-14017/ (Markdown: https://insights.sbomify.com/CVE-2017-14017/index.md)","id":"CVE-2017-14017","markdown":"https://insights.sbomify.com/CVE-2017-14017/index.md","name":"CVE-2017-14017","record":{"aliases":["GHSA-7xjq-r49q-hwq9"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["code_execution"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"SCADA HMI software","requires_auth":"low_privilege","summary":"Remote attackers can execute arbitrary code via malicious DLLs in Progea Movicon SCADA/HMI due to uncontrolled search path elements.","user_interaction":"not_required","vuln_class":"other"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"movicon","vendor":"progea"}],"cvss":{"score":7.8,"severity":"high","source":"nvd","vector":"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-427","name":"Uncontrolled Search Path Element"}],"description":"An Uncontrolled Search Path Element issue was discovered in Progea Movicon Version 11.5.1181 and prior. An uncontrolled search path element vulnerability has been identified, which may allow a remote attacker without privileges to execute arbitrary code in the form of a malicious DLL file.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Other in Progea Movicon SCADA/HMI","id":"CVE-2017-14017","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"other","year":"2017"},"n_packages":0,"n_references":2,"next":{"headline":"Auth bypass in Ethicon Endo-Surgery Generator G11","id":"CVE-2017-14018"},"packages":[],"prev":{"headline":"Memory corruption in Advantech WebAccess","id":"CVE-2017-14016"},"products":["Progea Movicon SCADA/HMI"],"published":"2017-10-19","related":[{"cvss_score":10,"headline":"Auth bypass in n/a","id":"CVE-2011-2963","kev_date_added":null,"published":"2011-07-29"},{"cvss_score":7.8,"headline":"Memory corruption in n/a","id":"CVE-2012-1804","kev_date_added":null,"published":"2012-05-14"},{"cvss_score":6.7,"headline":"Privilege escalation in Progea Movicon SCADA/HMI","id":"CVE-2017-14019","kev_date_added":null,"published":"2017-10-19"},{"cvss_score":4.3,"headline":"Progea Movicon SCADA Exposure of Sensitive Information to an Unauthorized Actor","id":"CVE-2014-0778","kev_date_added":null,"published":"2014-04-19"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"Remote attackers can execute arbitrary code via malicious DLLs in Progea Movicon SCADA/HMI due to uncontrolled search path elements.","url":"https://insights.sbomify.com/CVE-2017-14017/"}