{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2017-14018 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-14018 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-14018 is a medium-severity authentication bypass vulnerability in Ethicon Endo-Surgery Generator G11, published on 5 Dec 2017. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-14018 and fix it if it is affected.\n\nWhat it is: CVE-2017-14018 is a medium-severity authentication bypass vulnerability in Ethicon Endo-Surgery Generator G11, published on 5 Dec 2017. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-14018 in the wild and no public exploit code.\n\nAffected product: Ethicon Endo-Surgery Generator G11. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-14018/ (Markdown: https://insights.sbomify.com/CVE-2017-14018/index.md)","id":"CVE-2017-14018","markdown":"https://insights.sbomify.com/CVE-2017-14018/index.md","name":"CVE-2017-14018","record":{"aliases":["GHSA-4w94-8ff7-4xmw"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["security_bypass","denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Surgical generator","requires_auth":"none","summary":"Attackers can bypass authentication to connect unauthorized devices to the surgical generator, compromising integrity and availability.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"endo-surgery_generator_gen11_firmware","vendor":"ethicon"}],"cvss":{"score":4.8,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:P/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:L","version":"3.0"},"cwes":[{"id":"CWE-287","name":"Improper Authentication"}],"description":"An improper authentication issue was discovered in Johnson \u0026 Johnson Ethicon Endo-Surgery Generator Gen11, all versions released before November 29, 2017. The security authentication mechanism used between the Ethicon Endo-Surgery Generator Gen11 and single-patient use products can be bypassed, allowing for unauthorized devices to be connected to the generator, which could result in a loss of integrity or availability.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Auth bypass in Ethicon Endo-Surgery Generator G11","id":"CVE-2017-14018","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2017"},"n_packages":0,"n_references":2,"next":{"headline":"Privilege escalation in Progea Movicon SCADA/HMI","id":"CVE-2017-14019"},"packages":[],"prev":{"headline":"Other in Progea Movicon SCADA/HMI","id":"CVE-2017-14017"},"products":["Ethicon Endo-Surgery Generator G11"],"published":"2017-12-05","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"Attackers can bypass authentication to connect unauthorized devices to the surgical generator, compromising integrity and availability.","url":"https://insights.sbomify.com/CVE-2017-14018/"}