{"answers":{"affected":"It affects 4 products.","exploited":"There is no known exploitation of CVE-2017-14375 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-14375 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-14375 is a critical authentication bypass vulnerability in EMC VMAX Virtual Appliance (vApp) EMC Unisphere for VMAX Virtual Appliance versions prior to 8.4.0.15, EMC Solutions Enabler Virtual Appliance versions prior to 8.4.0.15, EMC VASA Virtual Appliance versions prior to 8.4.0.512, EMC VMAX Embedded Management (eManagement) versions prior to and including 1.4 (Enginuity Release 5977.1125.1125 and earlier), published on 1 Nov 2017. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-14375 and fix it if it is affected.\n\nWhat it is: CVE-2017-14375 is a critical authentication bypass vulnerability in EMC VMAX Virtual Appliance (vApp) EMC Unisphere for VMAX Virtual Appliance versions prior to 8.4.0.15, EMC Solutions Enabler Virtual Appliance versions prior to 8.4.0.15, EMC VASA Virtual Appliance versions prior to 8.4.0.512, EMC VMAX Embedded Management (eManagement) versions prior to and including 1.4 (Enginuity Release 5977.1125.1125 and earlier), published on 1 Nov 2017. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-14375 in the wild and no public exploit code.\n\nAffected product: EMC VMAX Virtual Appliance (vApp) EMC Unisphere for VMAX Virtual Appliance versions prior to 8.4.0.15, EMC Solutions Enabler Virtual Appliance versions prior to 8.4.0.15, EMC VASA Virtual Appliance versions prior to 8.4.0.512, EMC VMAX Embedded Management (eManagement) versions prior to and including 1.4 (Enginuity Release 5977.1125.1125 and earlier). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-14375/ (Markdown: https://insights.sbomify.com/CVE-2017-14375/index.md)","id":"CVE-2017-14375","markdown":"https://insights.sbomify.com/CVE-2017-14375/index.md","name":"CVE-2017-14375","record":{"aliases":["GHSA-3mf6-cpxv-733m"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["privilege_escalation","code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"EMC VMAX management","requires_auth":"none","summary":"Authentication bypass in EMC VMAX management appliances allows malicious users to compromise the system.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"dell","cpe":[{"product":"emc_unisphere","vendor":"dell"},{"product":"solutions_enabler","vendor":"emc"},{"product":"vasa","vendor":"emc"},{"product":"vmax_emanagement","vendor":"emc"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-290","name":"Authentication Bypass by Spoofing"}],"description":"EMC Unisphere for VMAX Virtual Appliance (vApp) versions prior to 8.4.0.15, EMC Solutions Enabler Virtual Appliance versions prior to 8.4.0.15, EMC VASA Virtual Appliance versions prior to 8.4.0.512, and EMC VMAX Embedded Management (eManagement) versions prior to and including 1.4 (Enginuity Release 5977.1125.1125 and earlier) contain an authentication bypass vulnerability that may potentially be exploited by malicious users to compromise the affected system.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Auth bypass in EMC VMAX Virtual Appliance (vApp) EMC Unisphere for VMAX Virtual Appliance versions prior to 8.4.0.15, EMC Solutions Enabler Virtual Appliance versions prior to 8.4.0.15, EMC VASA Virtual Appliance versions prior to 8.4.0.512, EMC VMAX Embedded Management (eManagement) versions prior to and including 1.4 (Enginuity Release 5977.1125.1125 and earlier)","id":"CVE-2017-14375","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2017"},"n_packages":0,"n_references":3,"next":{"headline":"Hardcoded credentials in EMC AppSync Server versions prior to 3.5.0.1","id":"CVE-2017-14376"},"packages":[],"prev":{"headline":"Hardcoded credentials in Dell Storage Manager 2016 Dell Storage Manager versions earlier than 16.3.20","id":"CVE-2017-14374"},"products":["EMC VMAX Virtual Appliance (vApp) EMC Unisphere for VMAX Virtual Appliance versions prior to 8.4.0.15, EMC Solutions Enabler Virtual Appliance versions prior to 8.4.0.15, EMC VASA Virtual Appliance versions prior to 8.4.0.512, EMC VMAX Embedded Management (eManagement) versions prior to and including 1.4 (Enginuity Release 5977.1125.1125 and earlier)"],"published":"2017-11-01","related":[{"cvss_score":9.8,"headline":"Code injection in n/a","id":"CVE-2016-6646","kev_date_added":null,"published":"2016-10-05"},{"cvss_score":9.8,"headline":"Path traversal in n/a","id":"CVE-2016-0889","kev_date_added":null,"published":"2016-04-15"},{"cvss_score":8.8,"headline":"Code injection in n/a","id":"CVE-2016-6645","kev_date_added":null,"published":"2016-10-05"},{"cvss_score":1.9,"headline":"Information disclosure in n/a","id":"CVE-2013-3287","kev_date_added":null,"published":"2013-11-02"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"Authentication bypass in EMC VMAX management appliances allows malicious users to compromise the system.","url":"https://insights.sbomify.com/CVE-2017-14375/"}