{"answers":{"affected":"It affects 7 products.","exploited":"There is no known exploitation of CVE-2017-18715 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-18715 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-18715 is a medium-severity cross-site scripting vulnerability in Netgear Ex6200 Firmware, published on 24 Apr 2020. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2017-18715 and fix it if it is affected.\n\nWhat it is: CVE-2017-18715 is a medium-severity cross-site scripting vulnerability in Netgear Ex6200 Firmware, published on 24 Apr 2020. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2017-18715 in the wild and no public exploit code.\n\nAffected product: Netgear Ex6200 Firmware. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-18715/ (Markdown: https://insights.sbomify.com/CVE-2017-18715/index.md)","id":"CVE-2017-18715","markdown":"https://insights.sbomify.com/CVE-2017-18715/index.md","name":"CVE-2017-18715","record":{"aliases":["GHSA-vf36-4466-h44f"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["security_bypass"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"NETGEAR WiFi Extender","requires_auth":"none","summary":"Reflected XSS in NETGEAR WiFi extenders allows attackers to execute scripts in user browsers, potentially leading to session hijacking or data theft.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"ex3700_firmware","vendor":"netgear"},{"product":"ex3800_firmware","vendor":"netgear"},{"product":"ex6100_firmware","vendor":"netgear"},{"product":"ex6120_firmware","vendor":"netgear"},{"product":"ex6150_firmware","vendor":"netgear"},{"product":"ex6200_firmware","vendor":"netgear"},{"product":"ex7000_firmware","vendor":"netgear"}],"cvss":{"score":5.2,"severity":"medium","source":"cna","vector":"CVSS:3.0/AC:L/AV:A/A:N/C:L/I:L/PR:N/S:C/UI:R","version":"3.0"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"}],"description":"Certain NETGEAR devices are affected by reflected XSS. This affects EX3700 before 1.0.0.66, EX3800 before 1.0.0.66, EX6100 before 1.0.2.20, EX6120 before 1.0.0.34, EX6150 before 1.0.0.36, EX6200 before 1.0.3.84, and EX7000 before 1.0.0.60.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cross-site scripting in n/a","id":"CVE-2017-18715","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"netgear:ex6200_firmware","products":["netgear:ex6200_firmware"],"type":"xss","year":"2017"},"n_packages":0,"n_references":1,"next":{"headline":"Memory corruption in n/a","id":"CVE-2017-18716"},"packages":[],"prev":{"headline":"Denial of service in n/a","id":"CVE-2017-18714"},"products":["n/a"],"published":"2020-04-24","related":[{"cvss_score":9.8,"headline":"Cross-site request forgery in n/a","id":"CVE-2021-32122","kev_date_added":null,"published":"2021-08-10"},{"cvss_score":8.8,"headline":"Misconfiguration in n/a","id":"CVE-2017-18747","kev_date_added":null,"published":"2020-04-23"},{"cvss_score":8.8,"headline":"Path traversal in n/a","id":"CVE-2017-18752","kev_date_added":null,"published":"2020-04-22"},{"cvss_score":8.8,"headline":"Auth bypass in n/a","id":"CVE-2017-18772","kev_date_added":null,"published":"2020-04-22"},{"cvss_score":8.7,"headline":"Netgear EX3700 mtd sub_41619C stack-based overflow","id":"CVE-2025-5934","kev_date_added":null,"published":"2025-06-10"},{"cvss_score":8.4,"headline":"Command injection in n/a","id":"CVE-2024-35519","kev_date_added":null,"published":"2024-10-14"},{"cvss_score":8.4,"headline":"Command injection in n/a","id":"CVE-2024-35522","kev_date_added":null,"published":"2024-10-11"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"Reflected XSS in NETGEAR WiFi extenders allows attackers to execute scripts in user browsers, potentially leading to session hijacking or data theft.","url":"https://insights.sbomify.com/CVE-2017-18715/"}