{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2017-20007 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-20007 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-20007 is a medium-severity vulnerability in Ingeteam INGEPAC DA AU, published on 25 Oct 2021. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-20007 and fix it if it is affected.\n\nWhat it is: CVE-2017-20007 is a medium-severity vulnerability in Ingeteam INGEPAC DA AU, published on 25 Oct 2021. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-20007 in the wild and no public exploit code.\n\nAffected product: Ingeteam INGEPAC DA AU. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-20007/ (Markdown: https://insights.sbomify.com/CVE-2017-20007/index.md)","id":"CVE-2017-20007","markdown":"https://insights.sbomify.com/CVE-2017-20007/index.md","name":"CVE-2017-20007","record":{"aliases":["GHSA-4hm5-q7h9-438p"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"INGEPAC DA AU","requires_auth":"none","summary":"Unauthenticated attackers can access sensitive configuration files via the web interface, potentially aiding further attacks.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"INCIBE","cpe":[{"product":"ingepac_da_au_firmware","vendor":"ingeteam"}],"cvss":{"score":5.3,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"Ingeteam INGEPAC DA AU AUC_1.13.0.28 (and before) web application allows access to a certain path that contains sensitive information that could be used by an attacker to execute more sophisticated attacks. An unauthenticated remote attacker with access to the device´s web service could exploit this vulnerability in order to obtain different configuration files.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information Exposure in INGEPAC DA AU","id":"CVE-2017-20007","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2017"},"n_packages":0,"n_references":1,"next":{"headline":"myCRED \u003c 1.7.8 - Reflected Cross-Site Scripting","id":"CVE-2017-20008"},"packages":[],"prev":{"headline":"Memory corruption in n/a","id":"CVE-2017-20006"},"products":["INGEPAC DA AU"],"published":"2021-10-25","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-17","vendors":["Ingeteam"]},"summary":"Unauthenticated attackers can access sensitive configuration files via the web interface, potentially aiding further attacks.","url":"https://insights.sbomify.com/CVE-2017-20007/"}