{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2017-20236 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-20236 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-20236 is a critical command injection vulnerability in ProSoft Technology ICX35-HWC Cellular Gateway, published on 3 Apr 2026. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-20236 and fix it if it is affected.\n\nWhat it is: CVE-2017-20236 is a critical command injection vulnerability in ProSoft Technology ICX35-HWC Cellular Gateway, published on 3 Apr 2026. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-20236 in the wild and no public exploit code.\n\nAffected product: ProSoft Technology ICX35-HWC Cellular Gateway. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-20236/ (Markdown: https://insights.sbomify.com/CVE-2017-20236/index.md)","id":"CVE-2017-20236","markdown":"https://insights.sbomify.com/CVE-2017-20236/index.md","name":"CVE-2017-20236","record":{"aliases":["GHSA-2v53-p8wg-cgj7"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["code_execution","privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"cellular gateway","requires_auth":"none","summary":"Remote attackers can inject system commands via the web interface to gain root privileges and execute arbitrary code on ProSoft ICX35-HWC gateways.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulnCheck","cpe":[{"product":"icx35-hwc_firmware","vendor":"prosoft-technology"}],"cvss":{"score":9.3,"severity":"critical","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"}],"description":"ProSoft Technology ICX35-HWC versions 1.3 and prior cellular gateways contain an input validation vulnerability in the web user interface that allows remote attackers to inject and execute system commands by submitting malicious input through unvalidated fields. Attackers can exploit this vulnerability to gain root privileges and execute arbitrary commands on the device through the accessible web interface.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"ProSoft Technology ICX35-HWC Command Injection via Web Interface","id":"CVE-2017-20236","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2017"},"n_packages":0,"n_references":2,"next":{"headline":"Hirschmann Industrial HiVision Authentication Bypass Remote Code Execution","id":"CVE-2017-20237"},"packages":[],"prev":{"headline":"ProSoft Technology ICX35-HWC Authentication Bypass","id":"CVE-2017-20235"},"products":["ICX35-HWC Cellular Gateway"],"published":"2026-04-03","related":[{"cvss_score":9.3,"headline":"ProSoft Technology ICX35-HWC Authentication Bypass","id":"CVE-2017-20235","kev_date_added":null,"published":"2026-04-03"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-05-25","vendors":["ProSoft Technology"]},"summary":"Remote attackers can inject system commands via the web interface to gain root privileges and execute arbitrary code on ProSoft ICX35-HWC gateways.","url":"https://insights.sbomify.com/CVE-2017-20236/"}