{"answers":{"affected":"It affects 7 products.","exploited":"There is no known exploitation of CVE-2017-2113 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-2113 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-2113 is a high-severity command injection vulnerability in I-O DATA DEVICE, INC. TS-PTCAM/POE, published on 28 Apr 2017. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-2113 and fix it if it is affected.\n\nWhat it is: CVE-2017-2113 is a high-severity command injection vulnerability in I-O DATA DEVICE, INC. TS-PTCAM/POE, published on 28 Apr 2017. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-2113 in the wild and no public exploit code.\n\nAffected product: I-O DATA DEVICE, INC. TS-PTCAM/POE. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-2113/ (Markdown: https://insights.sbomify.com/CVE-2017-2113/index.md)","id":"CVE-2017-2113","markdown":"https://insights.sbomify.com/CVE-2017-2113/index.md","name":"CVE-2017-2113","record":{"aliases":["GHSA-3922-7hw8-xghx"],"analysis":{"component_type":"iot_embedded","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"I-O DATA camera firmware","requires_auth":"none","summary":"Remote attackers can execute arbitrary OS commands on I-O DATA camera devices due to a buffer overflow in the firmware.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"jpcert","cpe":[{"product":"ts-ptcam\\/poe_firmware","vendor":"iodata"},{"product":"ts-ptcam_firmware","vendor":"iodata"},{"product":"ts-wlc2_firmware","vendor":"iodata"},{"product":"ts-wlce_firmware","vendor":"iodata"},{"product":"ts-wptcam2_firmware","vendor":"iodata"},{"product":"ts-wptcam_firmware","vendor":"iodata"},{"product":"ts-wrlc_firmware","vendor":"iodata"}],"cvss":{"score":8.8,"severity":"high","source":"nvd","vector":"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-119","name":"Improper Restriction of Operations within the Bounds of a Memory Buffer"}],"description":"Buffer overflow in TS-WPTCAM firmware version 1.18 and earlier, TS-WPTCAM2 firmware version 1.00, TS-WLCE firmware version 1.18 and earlier, TS-WLC2 firmware version 1.18 and earlier, TS-WRLC firmware version 1.17 and earlier, TS-PTCAM firmware version 1.18 and earlier, TS-PTCAM/POE firmware version 1.18 and earlier allows remote attackers to execute arbitrary OS commands via unspecified vectors.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Command injection in TS-PTCAM/POE","id":"CVE-2017-2113","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2017"},"n_packages":0,"n_references":3,"next":{"headline":"Cross-site scripting in Cybozu Office","id":"CVE-2017-2114"},"packages":[],"prev":{"headline":"Command injection in TS-PTCAM/POE","id":"CVE-2017-2112"},"products":["TS-PTCAM/POE","TS-WLC2","TS-WLCE","TS-WPTCAM","TS-WPTCAM2","TS-WRLC"],"published":"2017-04-28","related":[{"cvss_score":8.8,"headline":"Command injection in TS-PTCAM/POE","id":"CVE-2017-2112","kev_date_added":null,"published":"2017-04-28"},{"cvss_score":6.1,"headline":"Other in TS-PTCAM/POE","id":"CVE-2017-2111","kev_date_added":null,"published":"2017-04-28"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["I-O DATA DEVICE, INC."]},"summary":"Remote attackers can execute arbitrary OS commands on I-O DATA camera devices due to a buffer overflow in the firmware.","url":"https://insights.sbomify.com/CVE-2017-2113/"}