{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2017-2316 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-2316 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-2316 is a medium-severity memory corruption vulnerability in Juniper Networks NorthStar Controller Application, published on 24 Apr 2017. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-2316 and fix it if it is affected.\n\nWhat it is: CVE-2017-2316 is a medium-severity memory corruption vulnerability in Juniper Networks NorthStar Controller Application, published on 24 Apr 2017. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-2316 in the wild and no public exploit code.\n\nAffected product: Juniper Networks NorthStar Controller Application. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-2316/ (Markdown: https://insights.sbomify.com/CVE-2017-2316/index.md)","id":"CVE-2017-2316","markdown":"https://insights.sbomify.com/CVE-2017-2316/index.md","name":"CVE-2017-2316","record":{"aliases":["GHSA-phc6-j3wc-3jf6"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Network Controller","requires_auth":"low_privilege","summary":"An authenticated attacker can trigger a buffer overflow in the Juniper NorthStar Controller, causing a denial of service.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"juniper","cpe":[{"product":"northstar_controller","vendor":"juniper"}],"cvss":{"score":6.5,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H","version":"3.0"},"cwes":[{"id":"CWE-119","name":"Improper Restriction of Operations within the Bounds of a Memory Buffer"}],"description":"A buffer overflow vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow an authenticated malicious user to cause a buffer overflow leading to a denial of service.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Memory corruption in NorthStar Controller Application","id":"CVE-2017-2316","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2017"},"n_packages":0,"n_references":2,"next":{"headline":"Denial of service in NorthStar Controller Application","id":"CVE-2017-2317"},"packages":[],"prev":{"headline":"Denial of service in Junos OS on EX series Ethernet Switches with IPv6 enabled","id":"CVE-2017-2315"},"products":["NorthStar Controller Application"],"published":"2017-04-24","related":[{"cvss_score":10,"headline":"Information disclosure in NorthStar Controller Application","id":"CVE-2017-2320","kev_date_added":null,"published":"2017-04-24"},{"cvss_score":8.8,"headline":"Auth bypass in NorthStar Controller Application","id":"CVE-2017-2332","kev_date_added":null,"published":"2017-04-24"},{"cvss_score":8.6,"headline":"Denial of service in NorthStar Controller Application","id":"CVE-2017-2317","kev_date_added":null,"published":"2017-04-24"},{"cvss_score":8.6,"headline":"Other in NorthStar Controller Application","id":"CVE-2017-2321","kev_date_added":null,"published":"2017-04-24"},{"cvss_score":8.3,"headline":"Auth bypass in NorthStar Controller Application","id":"CVE-2017-2319","kev_date_added":null,"published":"2017-04-24"},{"cvss_score":7.5,"headline":"Denial of service in NorthStar Controller Application","id":"CVE-2017-2323","kev_date_added":null,"published":"2017-04-24"},{"cvss_score":7.5,"headline":"Information disclosure in NorthStar Controller Application","id":"CVE-2017-2334","kev_date_added":null,"published":"2017-04-24"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["Juniper Networks"]},"summary":"An authenticated attacker can trigger a buffer overflow in the Juniper NorthStar Controller, causing a denial of service.","url":"https://insights.sbomify.com/CVE-2017-2316/"}