{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2017-2320 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-2320 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-2320 is a critical vulnerability in Juniper Networks NorthStar Controller Application, published on 24 Apr 2017. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-2320 and fix it if it is affected.\n\nWhat it is: CVE-2017-2320 is a critical vulnerability in Juniper Networks NorthStar Controller Application, published on 24 Apr 2017. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-2320 in the wild and no public exploit code.\n\nAffected product: Juniper Networks NorthStar Controller Application. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-2320/ (Markdown: https://insights.sbomify.com/CVE-2017-2320/index.md)","id":"CVE-2017-2320","markdown":"https://insights.sbomify.com/CVE-2017-2320/index.md","name":"CVE-2017-2320","record":{"aliases":["GHSA-jw9m-g475-84fv"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["data_read","data_modify","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Juniper NorthStar Controller","requires_auth":"none","summary":"Unauthenticated attackers can cause denial of service, disclose information, and modify system components in Juniper NorthStar Controller.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"juniper","cpe":[{"product":"northstar_controller","vendor":"juniper"}],"cvss":{"score":10,"severity":"critical","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"A vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow an unauthenticated, unprivileged, network-based attacker to cause various denials of services leading to targeted information disclosure, modification of any component of the NorthStar system, including managed systems, and full denial of services to any systems under management which NorthStar interacts with using read-only or read-write credentials.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in NorthStar Controller Application","id":"CVE-2017-2320","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2017"},"n_packages":0,"n_references":2,"next":{"headline":"Other in NorthStar Controller Application","id":"CVE-2017-2321"},"packages":[],"prev":{"headline":"Auth bypass in NorthStar Controller Application","id":"CVE-2017-2319"},"products":["NorthStar Controller Application"],"published":"2017-04-24","related":[{"cvss_score":8.8,"headline":"Auth bypass in NorthStar Controller Application","id":"CVE-2017-2332","kev_date_added":null,"published":"2017-04-24"},{"cvss_score":8.6,"headline":"Denial of service in NorthStar Controller Application","id":"CVE-2017-2317","kev_date_added":null,"published":"2017-04-24"},{"cvss_score":8.6,"headline":"Other in NorthStar Controller Application","id":"CVE-2017-2321","kev_date_added":null,"published":"2017-04-24"},{"cvss_score":8.3,"headline":"Auth bypass in NorthStar Controller Application","id":"CVE-2017-2319","kev_date_added":null,"published":"2017-04-24"},{"cvss_score":7.5,"headline":"Denial of service in NorthStar Controller Application","id":"CVE-2017-2323","kev_date_added":null,"published":"2017-04-24"},{"cvss_score":7.5,"headline":"Information disclosure in NorthStar Controller Application","id":"CVE-2017-2334","kev_date_added":null,"published":"2017-04-24"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["Juniper Networks"]},"summary":"Unauthenticated attackers can cause denial of service, disclose information, and modify system components in Juniper NorthStar Controller.","url":"https://insights.sbomify.com/CVE-2017-2320/"}