{"answers":{"affected":"It affects 3 products.","exploited":"There is no known exploitation of CVE-2017-2685 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-2685 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-2685 is a high-severity vulnerability in SINUMERIK Integrate Operate Clients 2.x and 3.x, published on 1 Mar 2017. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-2685 and fix it if it is affected.\n\nWhat it is: CVE-2017-2685 is a high-severity vulnerability in SINUMERIK Integrate Operate Clients 2.x and 3.x, published on 1 Mar 2017. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-2685 in the wild and no public exploit code.\n\nAffected product: SINUMERIK Integrate Operate Clients 2.x and 3.x. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-2685/ (Markdown: https://insights.sbomify.com/CVE-2017-2685/index.md)","id":"CVE-2017-2685","markdown":"https://insights.sbomify.com/CVE-2017-2685/index.md","name":"CVE-2017-2685","record":{"aliases":["GHSA-857j-r82m-hrw9"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens SINUMERIK client","requires_auth":"none","summary":"An attacker can perform a man-in-the-middle attack to read and manipulate data in TLS sessions of Siemens SINUMERIK Integrate Operate Clients.","user_interaction":"not_required","vuln_class":"weak_cryptography"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"sinumerik_integrate_access_mymachine\\/ethernet","vendor":"siemens"},{"product":"sinumerik_integrate_operate_client","vendor":"siemens"},{"product":"sinumerik_operate","vendor":"siemens"}],"cvss":{"score":7.4,"severity":"high","source":"nvd","vector":"CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N","version":"3.0"},"cwes":[{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"},{"id":"CWE-693","name":"Protection Mechanism Failure"}],"description":"Siemens SINUMERIK Integrate Operate Clients between 2.0.3.00.016 (including) and 2.0.6 (excluding) and between 3.0.4.00.032 (including) and 3.0.6 (excluding) contain a vulnerability that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Weak cryptography in SINUMERIK Integrate Operate Clients 2.x and 3.x","id":"CVE-2017-2685","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"weak_cryptography","year":"2017"},"n_packages":0,"n_references":2,"next":{"headline":"Information disclosure in RUGGEDCOM ROX I All versions","id":"CVE-2017-2686"},"packages":[],"prev":{"headline":"Auth bypass in SIMATIC Logon All versions \u003c V1.5 SP3 Update 2","id":"CVE-2017-2684"},"products":["SINUMERIK Integrate Operate Clients 2.x and 3.x"],"published":"2017-03-01","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"An attacker can perform a man-in-the-middle attack to read and manipulate data in TLS sessions of Siemens SINUMERIK Integrate Operate Clients.","url":"https://insights.sbomify.com/CVE-2017-2685/"}