{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2017-4987 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-4987 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-4987 is a high-severity path traversal vulnerability in EMC VNX2 versions prior to OE for File 8.1.9.211, EMC VNX1 versions prior to OE for File 7.1.80.8, published on 19 Jun 2017. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2017-4987 and fix it if it is affected.\n\nWhat it is: CVE-2017-4987 is a high-severity path traversal vulnerability in EMC VNX2 versions prior to OE for File 8.1.9.211, EMC VNX1 versions prior to OE for File 7.1.80.8, published on 19 Jun 2017. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2017-4987 in the wild and no public exploit code.\n\nAffected product: EMC VNX2 versions prior to OE for File 8.1.9.211, EMC VNX1 versions prior to OE for File 7.1.80.8. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-4987/ (Markdown: https://insights.sbomify.com/CVE-2017-4987/index.md)","id":"CVE-2017-4987","markdown":"https://insights.sbomify.com/CVE-2017-4987/index.md","name":"CVE-2017-4987","record":{"aliases":["GHSA-x4f6-cxp5-xx88"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"EMC VNX storage system","requires_auth":"low_privilege","summary":"A local authenticated user can execute arbitrary code on EMC VNX Control Station by loading a malicious file from an uncontrolled search path.","user_interaction":"required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"dell","cpe":[{"product":"vnx1_firmware","vendor":"emc"},{"product":"vnx2_firmware","vendor":"emc"}],"cvss":{"score":7.3,"severity":"high","source":"nvd","vector":"CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-427","name":"Uncontrolled Search Path Element"}],"description":"In EMC VNX2 versions prior to OE for File 8.1.9.211 and VNX1 versions prior to OE for File 7.1.80.8, a local authenticated user can load a maliciously crafted file in the search path which may potentially allow the attacker to execute arbitrary code on the targeted VNX Control Station system, aka an uncontrolled search path vulnerability.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Path traversal in EMC VNX2 versions prior to OE for File 8.1.9.211, EMC VNX1 versions prior to OE for File 7.1.80.8","id":"CVE-2017-4987","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2017"},"n_packages":0,"n_references":2,"next":{"headline":"Privilege escalation in EMC Isilon OneFS 8.0.1.0, 8.0.0 8.0.0.3, 7.2.0 - 7.2.1.4, 7.1.x","id":"CVE-2017-4988"},"packages":[],"prev":{"headline":"Auth bypass in EMC ESRS Virtual Edition EMC ESRS VE 3.18 or earlier","id":"CVE-2017-4986"},"products":["EMC VNX2 versions prior to OE for File 8.1.9.211, EMC VNX1 versions prior to OE for File 7.1.80.8"],"published":"2017-06-19","related":[{"cvss_score":9.8,"headline":"Command injection in EMC VNX2 versions prior to OE for File 8.1.9.211, EMC VNX1 versions prior to OE for File 7.1.80.8","id":"CVE-2017-4984","kev_date_added":null,"published":"2017-06-19"},{"cvss_score":7.8,"headline":"Privilege escalation in EMC VNX2 versions prior to OE for File 8.1.9.211, EMC VNX1 versions prior to OE for File 7.1.80.8","id":"CVE-2017-4985","kev_date_added":null,"published":"2017-06-19"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"A local authenticated user can execute arbitrary code on EMC VNX Control Station by loading a malicious file from an uncontrolled search path.","url":"https://insights.sbomify.com/CVE-2017-4987/"}