{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2017-5144 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-5144 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-5144 is a critical missing authorization vulnerability in Carlo Gavazzi VMU-C EM and VMU-C PV, published on 13 Feb 2017. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-5144 and fix it if it is affected.\n\nWhat it is: CVE-2017-5144 is a critical missing authorization vulnerability in Carlo Gavazzi VMU-C EM and VMU-C PV, published on 13 Feb 2017. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-5144 in the wild and no public exploit code.\n\nAffected product: Carlo Gavazzi VMU-C EM and VMU-C PV. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-5144/ (Markdown: https://insights.sbomify.com/CVE-2017-5144/index.md)","id":"CVE-2017-5144","markdown":"https://insights.sbomify.com/CVE-2017-5144/index.md","name":"CVE-2017-5144","record":{"aliases":["GHSA-gm4w-w2wh-hv48"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["security_bypass","data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Energy management unit","requires_auth":"none","summary":"Attackers can access application functions without authentication on Carlo Gavazzi VMU-C devices, requiring firmware upgrades to mitigate.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"vmu-c_em_firmware","vendor":"carlosgavazzi"},{"product":"vmu-c_pv_firmware","vendor":"carlosgavazzi"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[],"description":"An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. The access control flaw allows access to most application functions without authentication.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authorization in Carlo Gavazzi VMU-C EM and VMU-C PV","id":"CVE-2017-5144","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2017"},"n_packages":0,"n_references":2,"next":{"headline":"Cross-site request forgery in Carlo Gavazzi VMU-C EM and VMU-C PV","id":"CVE-2017-5145"},"packages":[],"prev":{"headline":"Path traversal in Honeywell XL Web II Controller","id":"CVE-2017-5143"},"products":["Carlo Gavazzi VMU-C EM and VMU-C PV"],"published":"2017-02-13","related":[{"cvss_score":10,"headline":"Cross-site request forgery in Carlo Gavazzi VMU-C EM and VMU-C PV","id":"CVE-2017-5145","kev_date_added":null,"published":"2017-02-13"},{"cvss_score":7.5,"headline":"Information disclosure in Carlo Gavazzi VMU-C EM and VMU-C PV","id":"CVE-2017-5146","kev_date_added":null,"published":"2017-02-13"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"Attackers can access application functions without authentication on Carlo Gavazzi VMU-C devices, requiring firmware upgrades to mitigate.","url":"https://insights.sbomify.com/CVE-2017-5144/"}