{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2017-5162 exists.","fix":"No fix has been published for CVE-2017-5162 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-5162 is a critical missing authorization vulnerability in BINOM3 Electric Power Quality Meter, published on 13 Feb 2017. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-5162 and fix it if it is affected.\n\nWhat it is: CVE-2017-5162 is a critical missing authorization vulnerability in BINOM3 Electric Power Quality Meter, published on 13 Feb 2017. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2017-5162 exists.\n\nAffected product: BINOM3 Electric Power Quality Meter. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-5162/ (Markdown: https://insights.sbomify.com/CVE-2017-5162/index.md)","id":"CVE-2017-5162","markdown":"https://insights.sbomify.com/CVE-2017-5162/index.md","name":"CVE-2017-5162","record":{"aliases":["GHSA-pp9f-5m8v-g2pv"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["data_modify","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Electric Power Quality Meter","requires_auth":"none","summary":"Attackers can access application setup and configuration without authentication due to lack of remote service authentication in the power meter.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"universal_multifunctional_electric_power_quality_meter_firmware","vendor":"binom3"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"description":"An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Lack of authentication for remote service gives access to application set up and configuration.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":1,"nuclei":0,"refs":[{"date":null,"kind":"metasploit","ref":"auxiliary/scanner/http/binom3_login_config_pass_dump","stars":null,"title":"Binom3 Web Management Login Scanner, Config and Password File Dump"}],"tier":"weaponised"},"has_fix":null,"headline":"Missing authorization in BINOM3 Electric Power Quality Meter","id":"CVE-2017-5162","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2017"},"n_packages":0,"n_references":2,"next":{"headline":"Path traversal in Belden Hirschmann GECKO 2.0.00 and prior","id":"CVE-2017-5163"},"packages":[],"prev":{"headline":"Other in Sielco Sistemi Winlog SCADA Software prior to Version 3.02.01","id":"CVE-2017-5161"},"products":["BINOM3 Electric Power Quality Meter"],"published":"2017-02-13","related":[{"cvss_score":9.8,"headline":"Information disclosure in BINOM3 Electric Power Quality Meter","id":"CVE-2017-5166","kev_date_added":null,"published":"2017-02-13"},{"cvss_score":8.6,"headline":"Hardcoded credentials in BINOM3 Electric Power Quality Meter","id":"CVE-2017-5167","kev_date_added":null,"published":"2017-02-13"},{"cvss_score":7.6,"headline":"Cross-site request forgery in BINOM3 Electric Power Quality Meter","id":"CVE-2017-5165","kev_date_added":null,"published":"2017-02-13"},{"cvss_score":6.1,"headline":"Cross-site scripting in BINOM3 Electric Power Quality Meter","id":"CVE-2017-5164","kev_date_added":null,"published":"2017-02-13"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"},{"class":"attribution","licence":"BSD-3-Clause","name":"Metasploit"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"Attackers can access application setup and configuration without authentication due to lack of remote service authentication in the power meter.","url":"https://insights.sbomify.com/CVE-2017-5162/"}