{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2017-5163 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-5163 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-5163 is a medium-severity path traversal vulnerability in Belden Hirschmann GECKO 2.0.00 and prior, published on 13 Feb 2017. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-5163 and fix it if it is affected.\n\nWhat it is: CVE-2017-5163 is a medium-severity path traversal vulnerability in Belden Hirschmann GECKO 2.0.00 and prior, published on 13 Feb 2017. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-5163 in the wild and no public exploit code.\n\nAffected product: Belden Hirschmann GECKO 2.0.00 and prior. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-5163/ (Markdown: https://insights.sbomify.com/CVE-2017-5163/index.md)","id":"CVE-2017-5163","markdown":"https://insights.sbomify.com/CVE-2017-5163/index.md","name":"CVE-2017-5163","record":{"aliases":["GHSA-m7jp-2chf-r9qj"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Managed network switch","requires_auth":"none","summary":"An attacker can access password hashes via path traversal after an admin downloads a configuration file on Belden Hirschmann GECKO Lite switches.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"gecko_lite_managed_switch_firmware","vendor":"belden_hirschmann"}],"cvss":{"score":5.9,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.0"},"cwes":[{"id":"CWE-22","name":"Improper Limitation of a Pathname to a Restricted Directory"}],"description":"An issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. After an administrator downloads a configuration file, a copy of the configuration file, which includes hashes of user passwords, is saved to a location that is accessible without authentication by path traversal.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Path traversal in Belden Hirschmann GECKO 2.0.00 and prior","id":"CVE-2017-5163","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2017"},"n_packages":0,"n_references":2,"next":{"headline":"Cross-site scripting in BINOM3 Electric Power Quality Meter","id":"CVE-2017-5164"},"packages":[],"prev":{"headline":"Missing authorization in BINOM3 Electric Power Quality Meter","id":"CVE-2017-5162"},"products":["Belden Hirschmann GECKO 2.0.00 and prior"],"published":"2017-02-13","related":[{"cvss_score":7.1,"headline":"Cross-site request forgery in Belden Hirschmann GECKO","id":"CVE-2017-6038","kev_date_added":null,"published":"2017-06-30"},{"cvss_score":6.5,"headline":"Server-side request forgery in Belden Hirschmann GECKO","id":"CVE-2017-6036","kev_date_added":null,"published":"2017-06-30"},{"cvss_score":5.3,"headline":"Information disclosure in Belden Hirschmann GECKO","id":"CVE-2017-6040","kev_date_added":null,"published":"2017-06-30"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"An attacker can access password hashes via path traversal after an admin downloads a configuration file on Belden Hirschmann GECKO Lite switches.","url":"https://insights.sbomify.com/CVE-2017-5163/"}