{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2017-5165 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-5165 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-5165 is a high-severity vulnerability in BINOM3 Electric Power Quality Meter, published on 13 Feb 2017. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2017-5165 and fix it if it is affected.\n\nWhat it is: CVE-2017-5165 is a high-severity vulnerability in BINOM3 Electric Power Quality Meter, published on 13 Feb 2017. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2017-5165 in the wild and no public exploit code.\n\nAffected product: BINOM3 Electric Power Quality Meter. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-5165/ (Markdown: https://insights.sbomify.com/CVE-2017-5165/index.md)","id":"CVE-2017-5165","markdown":"https://insights.sbomify.com/CVE-2017-5165/index.md","name":"CVE-2017-5165","record":{"aliases":["GHSA-cf82-f44g-3hmr"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["data_modify","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Electric Power Quality Meter","requires_auth":"none","summary":"Attackers can force unauthorized configuration changes on BINOM3 power meters due to missing CSRF tokens, compromising device integrity.","user_interaction":"required","vuln_class":"csrf"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"universal_multifunctional_electric_power_quality_meter_firmware","vendor":"binom3"}],"cvss":{"score":7.6,"severity":"high","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:H","version":"3.0"},"cwes":[{"id":"CWE-352","name":"Cross-Site Request Forgery"}],"description":"An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. There is no CSRF Token generated per page and/or per (sensitive) function. Successful exploitation of this vulnerability can allow silent execution of unauthorized actions on the device such as configuration parameter changes, and saving modified configuration.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cross-site request forgery in BINOM3 Electric Power Quality Meter","id":"CVE-2017-5165","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"csrf","year":"2017"},"n_packages":0,"n_references":2,"next":{"headline":"Information disclosure in BINOM3 Electric Power Quality Meter","id":"CVE-2017-5166"},"packages":[],"prev":{"headline":"Cross-site scripting in BINOM3 Electric Power Quality Meter","id":"CVE-2017-5164"},"products":["BINOM3 Electric Power Quality Meter"],"published":"2017-02-13","related":[{"cvss_score":9.8,"headline":"Missing authorization in BINOM3 Electric Power Quality Meter","id":"CVE-2017-5162","kev_date_added":null,"published":"2017-02-13"},{"cvss_score":9.8,"headline":"Information disclosure in BINOM3 Electric Power Quality Meter","id":"CVE-2017-5166","kev_date_added":null,"published":"2017-02-13"},{"cvss_score":8.6,"headline":"Hardcoded credentials in BINOM3 Electric Power Quality Meter","id":"CVE-2017-5167","kev_date_added":null,"published":"2017-02-13"},{"cvss_score":6.1,"headline":"Cross-site scripting in BINOM3 Electric Power Quality Meter","id":"CVE-2017-5164","kev_date_added":null,"published":"2017-02-13"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"Attackers can force unauthorized configuration changes on BINOM3 power meters due to missing CSRF tokens, compromising device integrity.","url":"https://insights.sbomify.com/CVE-2017-5165/"}