{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2017-6016 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-6016 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-6016 is a high-severity vulnerability in LCDS Leao Consultoria e Desenvolvimento de Sistemas LTDA ME LAquis SCADA, published on 19 May 2017. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2017-6016 and fix it if it is affected.\n\nWhat it is: CVE-2017-6016 is a high-severity vulnerability in LCDS Leao Consultoria e Desenvolvimento de Sistemas LTDA ME LAquis SCADA, published on 19 May 2017. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2017-6016 in the wild and no public exploit code.\n\nAffected product: LCDS Leao Consultoria e Desenvolvimento de Sistemas LTDA ME LAquis SCADA. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-6016/ (Markdown: https://insights.sbomify.com/CVE-2017-6016/index.md)","id":"CVE-2017-6016","markdown":"https://insights.sbomify.com/CVE-2017-6016/index.md","name":"CVE-2017-6016","record":{"aliases":["GHSA-6qmp-h3rm-pc99"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["privilege_escalation","data_modify"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"SCADA software","requires_auth":"low_privilege","summary":"An authenticated user can modify application files to escalate privileges in LAquis SCADA, requiring an upgrade to mitigate.","user_interaction":"required","vuln_class":"privilege_escalation"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"ltda_me_laquis_scada","vendor":"leao_consultoria_e_desenvolvimento_de_sistemas"}],"cvss":{"score":7.3,"severity":"high","source":"nvd","vector":"CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-284","name":"Improper Access Control"}],"description":"An Improper Access Control issue was discovered in LCDS - Leao Consultoria e Desenvolvimento de Sistemas LTDA ME LAquis SCADA. The following versions are affected: Versions 4.1 and prior versions released before January 20, 2017. An Improper Access Control vulnerability has been identified, which may allow an authenticated user to modify application files to escalate privileges.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Privilege escalation in LCDS Leao Consultoria e Desenvolvimento de Sistemas LTDA ME LAquis SCADA","id":"CVE-2017-6016","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"privilege_escalation","year":"2017"},"n_packages":0,"n_references":2,"next":{"headline":"Denial of service in Schneider Electric Modicon M340 PLC","id":"CVE-2017-6017"},"packages":[],"prev":{"headline":"Path traversal in FactoryTalk Activation","id":"CVE-2017-6015"},"products":["LCDS Leao Consultoria e Desenvolvimento de Sistemas LTDA ME LAquis SCADA"],"published":"2017-05-19","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"An authenticated user can modify application files to escalate privileges in LAquis SCADA, requiring an upgrade to mitigate.","url":"https://insights.sbomify.com/CVE-2017-6016/"}