{"answers":{"affected":"It affects 15 products.","exploited":"There is no known exploitation of CVE-2017-6017 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-6017 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-6017 is a high-severity denial of service vulnerability in Schneider Electric Modicon M340 PLC, published on 30 Jun 2017. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-6017 and fix it if it is affected.\n\nWhat it is: CVE-2017-6017 is a high-severity denial of service vulnerability in Schneider Electric Modicon M340 PLC, published on 30 Jun 2017. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-6017 in the wild and no public exploit code.\n\nAffected product: Schneider Electric Modicon M340 PLC. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-6017/ (Markdown: https://insights.sbomify.com/CVE-2017-6017/index.md)","id":"CVE-2017-6017","markdown":"https://insights.sbomify.com/CVE-2017-6017/index.md","name":"CVE-2017-6017","record":{"aliases":["GHSA-4v7w-jq2v-52pw"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Modicon PLC","requires_auth":"none","summary":"Remote attackers can cause Schneider Electric Modicon PLCs to freeze via crafted packets, requiring physical reset to recover.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"bmxnoc0401_firmware","vendor":"schneider-electric"},{"product":"bmxnoe0100_firmware","vendor":"schneider-electric"},{"product":"bmxnoe0110_firmware","vendor":"schneider-electric"},{"product":"bmxnoe0110h_firmware","vendor":"schneider-electric"},{"product":"bmxnor0200h_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp341000_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp342000_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp3420102_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp3420102cl_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp342020_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp342020h_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp3420302_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp3420302h_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp342030_firmware","vendor":"schneider-electric"},{"product":"modicon_m340_bmxp342030h_firmware","vendor":"schneider-electric"}],"cvss":{"score":7.5,"severity":"high","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.0"},"cwes":[{"id":"CWE-400","name":"Uncontrolled Resource Consumption"}],"description":"A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Denial of service in Schneider Electric Modicon M340 PLC","id":"CVE-2017-6017","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2017"},"n_packages":0,"n_references":3,"next":{"headline":"Open redirect in B. Braun Medical SpaceCom","id":"CVE-2017-6018"},"packages":[],"prev":{"headline":"Privilege escalation in LCDS Leao Consultoria e Desenvolvimento de Sistemas LTDA ME LAquis SCADA","id":"CVE-2017-6016"},"products":["Schneider Electric Modicon M340 PLC"],"published":"2017-06-30","related":[{"cvss_score":5.4,"headline":"File upload in Schneider Electric Modicon PLC","id":"CVE-2015-6461","kev_date_added":null,"published":"2019-03-21"},{"cvss_score":5.4,"headline":"Cross-site scripting in Schneider Electric Modicon PLC","id":"CVE-2015-6462","kev_date_added":null,"published":"2019-03-21"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"Remote attackers can cause Schneider Electric Modicon PLCs to freeze via crafted packets, requiring physical reset to recover.","url":"https://insights.sbomify.com/CVE-2017-6017/"}