{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2017-6018 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-6018 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-6018 is a medium-severity vulnerability in B. Braun Medical SpaceCom, published on 30 Jun 2017. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2017-6018 and fix it if it is affected.\n\nWhat it is: CVE-2017-6018 is a medium-severity vulnerability in B. Braun Medical SpaceCom, published on 30 Jun 2017. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2017-6018 in the wild and no public exploit code.\n\nAffected product: B. Braun Medical SpaceCom. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-6018/ (Markdown: https://insights.sbomify.com/CVE-2017-6018/index.md)","id":"CVE-2017-6018","markdown":"https://insights.sbomify.com/CVE-2017-6018/index.md","name":"CVE-2017-6018","record":{"aliases":["GHSA-cmhp-37v4-3fmv"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Medical docking station","requires_auth":"none","summary":"Attackers can redirect users to malicious URLs via the SpaceCom module's web server, potentially facilitating phishing attacks against medical staff.","user_interaction":"required","vuln_class":"open_redirect"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"station_firmware","vendor":"bbraun"}],"cvss":{"score":6.1,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","version":"3.0"},"cwes":[{"id":"CWE-601","name":"URL Redirection to Untrusted Site"}],"description":"An open redirect issue was discovered in B. Braun Medical SpaceCom module, which is integrated into the SpaceStation docking station: SpaceStation with SpaceCom module (integrated as part number 8713142U), software versions prior to Version 012U000040, and SpaceStation (part number 8713140U) with installed SpaceCom module (part number 8713160U), software versions prior to Version 012U000040. The web server of the affected product accepts untrusted input which could allow attackers to redirect the request to an unintended URL contained within untrusted input.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Open redirect in B. Braun Medical SpaceCom","id":"CVE-2017-6018","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"open_redirect","year":"2017"},"n_packages":0,"n_references":1,"next":{"headline":"Denial of service in Schneider Electric Conext ComBox","id":"CVE-2017-6019"},"packages":[],"prev":{"headline":"Denial of service in Schneider Electric Modicon M340 PLC","id":"CVE-2017-6017"},"products":["B. Braun Medical SpaceCom"],"published":"2017-06-30","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"Attackers can redirect users to malicious URLs via the SpaceCom module's web server, potentially facilitating phishing attacks against medical staff.","url":"https://insights.sbomify.com/CVE-2017-6018/"}