{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2017-6019 exists.","fix":"No fix has been published for CVE-2017-6019 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-6019 is a high-severity denial of service vulnerability in Schneider Electric Conext ComBox, published on 7 Apr 2017. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-6019 and fix it if it is affected.\n\nWhat it is: CVE-2017-6019 is a high-severity denial of service vulnerability in Schneider Electric Conext ComBox, published on 7 Apr 2017. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2017-6019 exists.\n\nAffected product: Schneider Electric Conext ComBox. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-6019/ (Markdown: https://insights.sbomify.com/CVE-2017-6019/index.md)","id":"CVE-2017-6019","markdown":"https://insights.sbomify.com/CVE-2017-6019/index.md","name":"CVE-2017-6019","record":{"aliases":["GHSA-54v8-5r88-9g69"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Schneider Electric Conext ComBox","requires_auth":"none","summary":"Rapid requests to the device cause a reboot, leading to denial of service for industrial control systems.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"conext_combox_865-1058_firmware","vendor":"schneider-electric"}],"cvss":{"score":7.5,"severity":"high","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.0"},"cwes":[{"id":"CWE-400","name":"Uncontrolled Resource Consumption"}],"description":"An issue was discovered in Schneider Electric Conext ComBox, model 865-1058, all firmware versions prior to V3.03 BN 830. A series of rapid requests to the device may cause it to reboot.","ecosystems":[],"exploits":{"exploitdb":1,"first_seen":"2017-03-02","github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[{"date":"2017-03-02","kind":"exploitdb","ref":"41537","stars":null,"title":"Conext ComBox 865-1058 - Denial of Service"}],"tier":"weaponised"},"has_fix":null,"headline":"Denial of service in Schneider Electric Conext ComBox","id":"CVE-2017-6019","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2017"},"n_packages":0,"n_references":4,"next":{"headline":"Leao Consultoria e Desenvolvimento de Sistemas (LCDS) LTDA ME LAquis SCADA software versions prior to version 4.1.0.3237 do not neutralize e","id":"CVE-2017-6020"},"packages":[],"prev":{"headline":"Open redirect in B. Braun Medical SpaceCom","id":"CVE-2017-6018"},"products":["Schneider Electric Conext ComBox"],"published":"2017-04-07","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"},{"class":"attribution","licence":"GPL-2.0-or-later","name":"Exploit-DB"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"Rapid requests to the device cause a reboot, leading to denial of service for industrial control systems.","url":"https://insights.sbomify.com/CVE-2017-6019/"}