{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2017-6032 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-6032 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-6032 is a medium-severity vulnerability in Schneider Electric Modicon Modbus Protocol, published on 30 Jun 2017. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-6032 and fix it if it is affected.\n\nWhat it is: CVE-2017-6032 is a medium-severity vulnerability in Schneider Electric Modicon Modbus Protocol, published on 30 Jun 2017. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-6032 in the wild and no public exploit code.\n\nAffected product: Schneider Electric Modicon Modbus Protocol. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-6032/ (Markdown: https://insights.sbomify.com/CVE-2017-6032/index.md)","id":"CVE-2017-6032","markdown":"https://insights.sbomify.com/CVE-2017-6032/index.md","name":"CVE-2017-6032","record":{"aliases":["GHSA-cqjv-5r3c-4hmg"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Modicon Modbus Protocol","requires_auth":"none","summary":"Attackers can exploit session weaknesses in the Modicon Modbus protocol to perform brute-force attacks, bypassing security controls in industrial control systems.","user_interaction":"not_required","vuln_class":"security_feature_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"modbus_firmware","vendor":"schneider-electric"}],"cvss":{"score":5.3,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.0"},"cwes":[{"id":"CWE-358","name":"Improperly Implemented Security Check for Standard"},{"id":"CWE-657","name":"Violation of Secure Design Principles"}],"description":"A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Security feature bypass in Schneider Electric Modicon Modbus Protocol","id":"CVE-2017-6032","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"security_feature_bypass","year":"2017"},"n_packages":0,"n_references":2,"next":{"headline":"Other in Schneider Electric Interactive Graphical SCADA System Software","id":"CVE-2017-6033"},"packages":[],"prev":{"headline":"Code injection in Certec EDV GmbH atvise scada","id":"CVE-2017-6031"},"products":["Schneider Electric Modicon Modbus Protocol"],"published":"2017-06-30","related":[{"cvss_score":9.8,"headline":"Schneider Electric Modicon Modbus Protocol Authentication Bypass by Capture-replay","id":"CVE-2017-6034","kev_date_added":null,"published":"2017-06-30"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"Attackers can exploit session weaknesses in the Modicon Modbus protocol to perform brute-force attacks, bypassing security controls in industrial control systems.","url":"https://insights.sbomify.com/CVE-2017-6032/"}