{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2017-6206 exists.","fix":"No fix has been published for CVE-2017-6206 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-6206 is a high-severity vulnerability in n/a, published on 23 Feb 2017. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-6206 and fix it if it is affected.\n\nWhat it is: CVE-2017-6206 is a high-severity vulnerability in n/a, published on 23 Feb 2017. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2017-6206 exists.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-6206/ (Markdown: https://insights.sbomify.com/CVE-2017-6206/index.md)","id":"CVE-2017-6206","markdown":"https://insights.sbomify.com/CVE-2017-6206/index.md","name":"CVE-2017-6206","record":{"aliases":["GHSA-c4w2-2wpw-p67g"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"D-Link Smart Switch","requires_auth":"none","summary":"Unauthenticated attackers can disclose sensitive information from D-Link Websmart switches via unspecified vectors.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"websmart_dgs-1510_series_firmware","vendor":"dlink"}],"cvss":{"score":7.5,"severity":"high","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.0"},"cwes":[{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"D-Link DGS-1510-28XMP, DGS-1510-28X, DGS-1510-52X, DGS-1510-52, DGS-1510-28P, DGS-1510-28, and DGS-1510-20 Websmart devices with firmware before 1.31.B003 allow attackers to conduct Unauthenticated Information Disclosure attacks via unspecified vectors.","ecosystems":[],"exploits":{"exploitdb":1,"first_seen":"2017-03-20","github_poc":1,"max_poc_stars":2,"metasploit":0,"nuclei":0,"refs":[{"date":"2017-03-20T17:24:22Z","kind":"github_poc","ref":"https://github.com/varangamin/CVE-2017-6206","stars":2,"title":"The DGS-1510 Websmart switch series firmware has been found to have security vulneratiblies. The vulnerabilities include unauthenticated command bypass and unauthenticated information disclosure."},{"date":"2017-03-20","kind":"exploitdb","ref":"41662","stars":null,"title":"D-Link DGS-1510 - Multiple Vulnerabilities"}],"tier":"weaponised"},"has_fix":null,"headline":"Information disclosure in n/a","id":"CVE-2017-6206","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2017"},"n_packages":0,"n_references":4,"next":{"headline":"Memory corruption in n/a","id":"CVE-2017-6209"},"packages":[],"prev":{"headline":"Command injection in n/a","id":"CVE-2017-6205"},"products":["n/a"],"published":"2017-02-23","related":[{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2017-6205","kev_date_added":null,"published":"2017-02-23"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"},{"class":"attribution","licence":"GPL-2.0-or-later","name":"Exploit-DB"},{"class":"open","licence":"CC0","name":"PoC-in-GitHub"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"Unauthenticated attackers can disclose sensitive information from D-Link Websmart switches via unspecified vectors.","url":"https://insights.sbomify.com/CVE-2017-6206/"}