{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2017-7575 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-7575 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-7575 is a critical vulnerability in n/a, published on 6 Apr 2017. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-7575 and fix it if it is affected.\n\nWhat it is: CVE-2017-7575 is a critical vulnerability in n/a, published on 6 Apr 2017. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-7575 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-7575/ (Markdown: https://insights.sbomify.com/CVE-2017-7575/index.md)","id":"CVE-2017-7575","markdown":"https://insights.sbomify.com/CVE-2017-7575/index.md","name":"CVE-2017-7575","record":{"aliases":["GHSA-8m3c-jvc6-q3hr"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["data_read","code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Modicon PLC","requires_auth":"none","summary":"Remote attackers can extract the application-protection password via Modbus, enabling arbitrary download, modification, and upload of the PLC application.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"modicon_tm221ce16r_firmware","vendor":"schneider-electric"}],"cvss":{"score":9.8,"severity":"critical","source":"cisa-adp","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"Schneider Electric Modicon TM221CE16R 1.3.3.3 devices allow remote attackers to discover the application-protection password via a \\x00\\x01\\x00\\x00\\x00\\x05\\x01\\x5a\\x00\\x03\\x00 request to the Modbus port (502/tcp). Subsequently the application may be arbitrarily downloaded, modified, and uploaded.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in n/a","id":"CVE-2017-7575","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2017"},"n_packages":0,"n_references":3,"next":{"headline":"Hardcoded credentials in n/a","id":"CVE-2017-7576"},"packages":[],"prev":{"headline":"Hardcoded credentials in n/a","id":"CVE-2017-7574"},"products":["n/a"],"published":"2017-04-06","related":[{"cvss_score":10,"headline":"Hardcoded credentials in n/a","id":"CVE-2017-7574","kev_date_added":null,"published":"2017-04-06"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-05-29","vendors":["n/a"]},"summary":"Remote attackers can extract the application-protection password via Modbus, enabling arbitrary download, modification, and upload of the PLC application.","url":"https://insights.sbomify.com/CVE-2017-7575/"}