{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2017-7907 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-7907 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-7907 is a medium-severity vulnerability in Schneider Electric Wonderware Historian Client, published on 19 May 2017. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2017-7907 and fix it if it is affected.\n\nWhat it is: CVE-2017-7907 is a medium-severity vulnerability in Schneider Electric Wonderware Historian Client, published on 19 May 2017. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2017-7907 in the wild and no public exploit code.\n\nAffected product: Schneider Electric Wonderware Historian Client. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-7907/ (Markdown: https://insights.sbomify.com/CVE-2017-7907/index.md)","id":"CVE-2017-7907","markdown":"https://insights.sbomify.com/CVE-2017-7907/index.md","name":"CVE-2017-7907","record":{"aliases":["GHSA-hvqh-vmw8-vhgv"],"analysis":{"component_type":"desktop_application","fix_type":"patch","impacts":["denial_of_service","data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Wonderware Historian Client","requires_auth":"low_privilege","summary":"An XXE vulnerability in Schneider Electric Wonderware Historian Client allows attackers to cause denial of service or disclose server file contents.","user_interaction":"required","vuln_class":"xxe"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"wonderware_historian_client","vendor":"schneider-electric"}],"cvss":{"score":6.6,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:H","version":"3.0"},"cwes":[{"id":"CWE-611","name":"Improper Restriction of XML External Entity Reference"}],"description":"An Improper XML Parser Configuration issue was discovered in Schneider Electric Wonderware Historian Client 2014 R2 SP1 and prior. An improperly restricted XML parser (with improper restriction of XML external entity reference, or XXE) may allow an attacker to enter malicious input through the application which could cause a denial of service or disclose file contents from a server or connected network.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"XML external entity in Schneider Electric Wonderware Historian Client","id":"CVE-2017-7907","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xxe","year":"2017"},"n_packages":0,"n_references":4,"next":{"headline":"Memory corruption in GE Communicator","id":"CVE-2017-7908"},"packages":[],"prev":{"headline":"Cross-site request forgery in ABB IP GATEWAY","id":"CVE-2017-7906"},"products":["Schneider Electric Wonderware Historian Client"],"published":"2017-05-19","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"An XXE vulnerability in Schneider Electric Wonderware Historian Client allows attackers to cause denial of service or disclose server file contents.","url":"https://insights.sbomify.com/CVE-2017-7907/"}