{"answers":{"affected":"It affects 6 products.","exploited":"There is no known exploitation of CVE-2017-7913 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-7913 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-7913 is a critical vulnerability in Moxa OnCell, published on 29 May 2017. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-7913 and fix it if it is affected.\n\nWhat it is: CVE-2017-7913 is a critical vulnerability in Moxa OnCell, published on 29 May 2017. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-7913 in the wild and no public exploit code.\n\nAffected product: Moxa OnCell. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-7913/ (Markdown: https://insights.sbomify.com/CVE-2017-7913/index.md)","id":"CVE-2017-7913","markdown":"https://insights.sbomify.com/CVE-2017-7913/index.md","name":"CVE-2017-7913","record":{"aliases":["GHSA-5q29-f827-q5cx"],"analysis":{"component_type":"network_device","fix_type":"patch","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Moxa OnCell gateway","requires_auth":"none","summary":"Attackers can read plaintext passwords from configuration files in Moxa OnCell devices, potentially leading to unauthorized access.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"oncell_5004-hspa_firmware","vendor":"moxa"},{"product":"oncell_5104-hsdpa_firmware","vendor":"moxa"},{"product":"oncell_5104-hspa_firmware","vendor":"moxa"},{"product":"oncell_g3110-hsdpa_firmware","vendor":"moxa"},{"product":"oncell_g3110-hspa_firmware","vendor":"moxa"},{"product":"oncell_g3150-hsdpa_firmware","vendor":"moxa"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-522","name":"Insufficiently Protected Credentials"},{"id":"CWE-256","name":"Plaintext Storage of a Password"}],"description":"A Plaintext Storage of a Password issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. The application's configuration file contains parameters that represent passwords in plaintext.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in Moxa OnCell","id":"CVE-2017-7913","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2017"},"n_packages":0,"n_references":1,"next":{"headline":"Missing authorization in Rockwell Automation PanelView Plus 6 700-1500","id":"CVE-2017-7914"},"packages":[],"prev":{"headline":"Auth bypass in SRN-4000","id":"CVE-2017-7912"},"products":["Moxa OnCell"],"published":"2017-05-29","related":[{"cvss_score":9.8,"headline":"Auth bypass in Moxa OnCell","id":"CVE-2017-7915","kev_date_added":null,"published":"2017-05-29"},{"cvss_score":8.8,"headline":"Cross-site request forgery in Moxa OnCell","id":"CVE-2017-7917","kev_date_added":null,"published":"2017-05-29"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"Attackers can read plaintext passwords from configuration files in Moxa OnCell devices, potentially leading to unauthorized access.","url":"https://insights.sbomify.com/CVE-2017-7913/"}