{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2017-7920 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-7920 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-7920 is a high-severity missing authorization vulnerability in ABB VSN300 WiFi Logger Card, published on 7 Aug 2017. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-7920 and fix it if it is affected.\n\nWhat it is: CVE-2017-7920 is a high-severity missing authorization vulnerability in ABB VSN300 WiFi Logger Card, published on 7 Aug 2017. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-7920 in the wild and no public exploit code.\n\nAffected product: ABB VSN300 WiFi Logger Card. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-7920/ (Markdown: https://insights.sbomify.com/CVE-2017-7920/index.md)","id":"CVE-2017-7920","markdown":"https://insights.sbomify.com/CVE-2017-7920/index.md","name":"CVE-2017-7920","record":{"aliases":["GHSA-wwfh-wcfq-86q2"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"ABB WiFi Logger Card","requires_auth":"none","summary":"Unauthenticated attackers can access internal status and connected device information via a specific URL on the ABB VSN300 WiFi Logger Card.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"vsn300_firmware","vendor":"abb"},{"product":"vsn300_for_react_firmware","vendor":"abb"}],"cvss":{"score":7.5,"severity":"high","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.0"},"cwes":[{"id":"CWE-287","name":"Improper Authentication"}],"description":"An Improper Authentication issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access internal information about status and connected devices without authenticating.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authorization in ABB VSN300 WiFi Logger Card","id":"CVE-2017-7920","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2017"},"n_packages":0,"n_references":3,"next":{"headline":"Hikvision Multiple Products Improper Authentication","id":"CVE-2017-7921"},"packages":[],"prev":{"headline":"Auth bypass in Newport XPS-Cx, XPS-Qx","id":"CVE-2017-7919"},"products":["ABB VSN300 WiFi Logger Card"],"published":"2017-08-07","related":[{"cvss_score":6.5,"headline":"Missing authorization in ABB VSN300 WiFi Logger Card","id":"CVE-2017-7916","kev_date_added":null,"published":"2017-08-07"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"Unauthenticated attackers can access internal status and connected device information via a specific URL on the ABB VSN300 WiFi Logger Card.","url":"https://insights.sbomify.com/CVE-2017-7920/"}