{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2017-7970 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-7970 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-7970 is a medium-severity server-side request forgery vulnerability in Schneider Electric SE Citect Anywhere, published on 25 Sep 2017. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-7970 and fix it if it is affected.\n\nWhat it is: CVE-2017-7970 is a medium-severity server-side request forgery vulnerability in Schneider Electric SE Citect Anywhere, published on 25 Sep 2017. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-7970 in the wild and no public exploit code.\n\nAffected product: Schneider Electric SE Citect Anywhere. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-7970/ (Markdown: https://insights.sbomify.com/CVE-2017-7970/index.md)","id":"CVE-2017-7970","markdown":"https://insights.sbomify.com/CVE-2017-7970/index.md","name":"CVE-2017-7970","record":{"aliases":["GHSA-mgw3-q3cc-425w"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["data_read","security_bypass"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"SCADA Anywhere","requires_auth":"none","summary":"Attackers can specify arbitrary server targets in connection requests, potentially accessing internal resources or bypassing security controls in Schneider Electric SCADA systems.","user_interaction":"not_required","vuln_class":"ssrf"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"citect_anywhere","vendor":"schneider-electric"},{"product":"powerscada_anywhere","vendor":"schneider-electric"}],"cvss":{"score":6.5,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.0"},"cwes":[],"description":"A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the ability to specify Arbitrary Server Target Nodes in connection requests to the Secure Gateway and Server components.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Server-side request forgery in Citect Anywhere","id":"CVE-2017-7970","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"ssrf","year":"2017"},"n_packages":0,"n_references":3,"next":{"headline":"Weak cryptography in Citect Anywhere","id":"CVE-2017-7971"},"packages":[],"prev":{"headline":"Cross-site request forgery in Citect Anywhere","id":"CVE-2017-7969"},"products":["Citect Anywhere","PowerSCADA Anywhere"],"published":"2017-09-25","related":[{"cvss_score":8.8,"headline":"Cross-site request forgery in Citect Anywhere","id":"CVE-2017-7969","kev_date_added":null,"published":"2017-09-25"},{"cvss_score":6.5,"headline":"Weak cryptography in Citect Anywhere","id":"CVE-2017-7971","kev_date_added":null,"published":"2017-09-25"},{"cvss_score":5.5,"headline":"Command injection in Citect Anywhere","id":"CVE-2017-7972","kev_date_added":null,"published":"2017-09-25"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-17","vendors":["Schneider Electric SE"]},"summary":"Attackers can specify arbitrary server targets in connection requests, potentially accessing internal resources or bypassing security controls in Schneider Electric SCADA systems.","url":"https://insights.sbomify.com/CVE-2017-7970/"}