{"answers":{"affected":"It affects 6 products.","exploited":"There is no known exploitation of CVE-2017-7995 in the wild and no public exploit code.","fix":"Product is end of life, replace it.","what":"CVE-2017-7995 is a low-severity vulnerability in Novell Suse Linux Enterprise Server, published on 3 May 2017. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-7995 and fix it if it is affected.\n\nWhat it is: CVE-2017-7995 is a low-severity vulnerability in Novell Suse Linux Enterprise Server, published on 3 May 2017. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-7995 in the wild and no public exploit code.\n\nAffected product: Novell Suse Linux Enterprise Server. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-7995/ (Markdown: https://insights.sbomify.com/CVE-2017-7995/index.md)","id":"CVE-2017-7995","markdown":"https://insights.sbomify.com/CVE-2017-7995/index.md","name":"CVE-2017-7995","record":{"aliases":["DEBIAN-CVE-2017-7995","GHSA-x43f-7h79-3278"],"analysis":{"component_type":"operating_system","fix_type":"end_of_life","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Xen PV guest","requires_auth":"low_privilege","summary":"A flaw in Xen PV guests allowed host PCI device memory reads before permission checks, leading to information disclosure.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"suse_linux_enterprise_point_of_sale","vendor":"novell"},{"product":"suse_linux_enterprise_server","vendor":"novell"},{"product":"manager","vendor":"suse"},{"product":"manager_proxy","vendor":"suse"},{"product":"openstack_cloud","vendor":"suse"},{"product":"xen","vendor":"xen"}],"cvss":{"score":3.8,"severity":"low","source":"nvd","vector":"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N","version":"3.0"},"cwes":[{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"Xen PV guest before Xen 4.3 checked access permissions to MMIO ranges only after accessing them, allowing host PCI device space memory reads, leading to information disclosure. This is an error in the get_user function. NOTE: the upstream Xen Project considers versions before 4.5.x to be EOL.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":true,"headline":"Information disclosure in n/a","id":"CVE-2017-7995","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"novell:suse_linux_enterprise_server","products":["novell:suse_linux_enterprise_server","xen:xen"],"type":"information_disclosure","year":"2017"},"n_packages":0,"n_references":3,"next":{"headline":"SQL injection in n/a","id":"CVE-2017-7997"},"packages":[],"prev":{"headline":"Null dereference in n/a","id":"CVE-2017-7994"},"products":["n/a"],"published":"2017-05-03","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"A flaw in Xen PV guests allowed host PCI device memory reads before permission checks, leading to information disclosure.","url":"https://insights.sbomify.com/CVE-2017-7995/"}