{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2017-9134 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-9134 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-9134 is a high-severity vulnerability in n/a, published on 21 May 2017. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-9134 and fix it if it is affected.\n\nWhat it is: CVE-2017-9134 is a high-severity vulnerability in n/a, published on 21 May 2017. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-9134 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-9134/ (Markdown: https://insights.sbomify.com/CVE-2017-9134/index.md)","id":"CVE-2017-9134","markdown":"https://insights.sbomify.com/CVE-2017-9134/index.md","name":"CVE-2017-9134","record":{"aliases":["GHSA-2h45-qgpq-hq8p"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["data_read","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Mimosa wireless radio","requires_auth":"none","summary":"Unauthenticated attackers can view device serial numbers to trigger remote factory resets, causing denial of service on Mimosa radios.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"backhaul_radios","vendor":"mimosa"},{"product":"client_radios","vendor":"mimosa"}],"cvss":{"score":7.5,"severity":"high","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.0"},"cwes":[{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"An information-leakage issue was discovered on Mimosa Client Radios before 2.2.3 and Mimosa Backhaul Radios before 2.2.3. There is a page in the web interface that will show you the device's serial number, regardless of whether or not you have logged in. This information-leakage issue is relevant because there is another page (accessible without any authentication) that allows you to remotely factory reset the device simply by entering the serial number.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in n/a","id":"CVE-2017-9134","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2017"},"n_packages":0,"n_references":1,"next":{"headline":"Command injection in n/a","id":"CVE-2017-9135"},"packages":[],"prev":{"headline":"Command injection in n/a","id":"CVE-2017-9133"},"products":["n/a"],"published":"2017-05-21","related":[{"cvss_score":8.8,"headline":"Command injection in n/a","id":"CVE-2017-9133","kev_date_added":null,"published":"2017-05-21"},{"cvss_score":8.8,"headline":"Command injection in n/a","id":"CVE-2017-9135","kev_date_added":null,"published":"2017-05-21"},{"cvss_score":7.5,"headline":"Command injection in n/a","id":"CVE-2017-9131","kev_date_added":null,"published":"2017-05-21"},{"cvss_score":7.5,"headline":"Hardcoded credentials in n/a","id":"CVE-2017-9132","kev_date_added":null,"published":"2017-05-21"},{"cvss_score":7.5,"headline":"Path traversal in n/a","id":"CVE-2017-9136","kev_date_added":null,"published":"2017-05-21"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"Unauthenticated attackers can view device serial numbers to trigger remote factory resets, causing denial of service on Mimosa radios.","url":"https://insights.sbomify.com/CVE-2017-9134/"}