{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2017-9276 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-9276 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-9276 is a medium-severity cross-site scripting vulnerability in NetIQ Access Manager, published on 2 Mar 2018. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2017-9276 and fix it if it is affected.\n\nWhat it is: CVE-2017-9276 is a medium-severity cross-site scripting vulnerability in NetIQ Access Manager, published on 2 Mar 2018. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2017-9276 in the wild and no public exploit code.\n\nAffected product: NetIQ Access Manager. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-9276/ (Markdown: https://insights.sbomify.com/CVE-2017-9276/index.md)","id":"CVE-2017-9276","markdown":"https://insights.sbomify.com/CVE-2017-9276/index.md","name":"CVE-2017-9276","record":{"aliases":["GHSA-77p6-g8qp-84c3"],"analysis":{"component_type":"web_application","fix_type":"upgrade","impacts":["code_execution","account_takeover"],"network_reachable":"yes","non_default_config":false,"product_category":"Novell Access Manager","requires_auth":"none","summary":"An attacker can execute arbitrary scripts in the victim's browser via the 'a' parameter in Novell Access Manager iManager.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"microfocus","cpe":[{"product":"access_manager","vendor":"netiq"}],"cvss":{"score":5.4,"severity":"medium","source":"cna","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N","version":"3.0"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"}],"description":"Novell Access Manager iManager before 4.3.3 did not validate parameters so that cross site scripting content could be reflected back into the result page using the \"a\" parameter.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"XSS Vulnerability in iManager","id":"CVE-2017-9276","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2017"},"n_packages":0,"n_references":1,"next":{"headline":"existing connection is being used even though eDirectory LDAP server is upgraded to EBA","id":"CVE-2017-9277"},"packages":[],"prev":{"headline":"NetIQ Identity Reporting XSS exposure","id":"CVE-2017-9275"},"products":["Access Manager"],"published":"2018-03-02","related":[{"cvss_score":9.8,"headline":"File upload in NetIQ Access Manager, Administrative Console","id":"CVE-2018-1342","kev_date_added":null,"published":"2018-01-26"},{"cvss_score":9.8,"headline":"Code injection in NetIQ Access Manager","id":"CVE-2017-14803","kev_date_added":null,"published":"2018-01-20"},{"cvss_score":9.8,"headline":"Information disclosure in NetIQ Access Manager","id":"CVE-2016-5757","kev_date_added":null,"published":"2017-03-23"},{"cvss_score":8.8,"headline":"File upload in NetIQ iManager","id":"CVE-2016-5750","kev_date_added":null,"published":"2017-03-23"},{"cvss_score":8.8,"headline":"Cross-site request forgery in NetIQ Access Manager","id":"CVE-2016-5758","kev_date_added":null,"published":"2017-03-23"},{"cvss_score":7.5,"headline":"Information disclosure in NetIQ Access Manager","id":"CVE-2016-5752","kev_date_added":null,"published":"2017-03-23"},{"cvss_score":7.5,"headline":"Information disclosure in NetIQ Access Manager","id":"CVE-2016-5754","kev_date_added":null,"published":"2017-03-23"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-17","vendors":["NetIQ"]},"summary":"An attacker can execute arbitrary scripts in the victim's browser via the 'a' parameter in Novell Access Manager iManager.","url":"https://insights.sbomify.com/CVE-2017-9276/"}