{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2017-9384 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-9384 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-9384 is a high-severity command injection vulnerability in n/a, published on 17 Jun 2019. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-9384 and fix it if it is affected.\n\nWhat it is: CVE-2017-9384 is a high-severity command injection vulnerability in n/a, published on 17 Jun 2019. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-9384 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-9384/ (Markdown: https://insights.sbomify.com/CVE-2017-9384/index.md)","id":"CVE-2017-9384","markdown":"https://insights.sbomify.com/CVE-2017-9384/index.md","name":"CVE-2017-9384","record":{"aliases":["GHSA-pp7x-qr4j-fm9r"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Vera home automation","requires_auth":"low_privilege","summary":"Attackers can execute arbitrary commands on Vera home automation devices via unsanitized input in the relay.sh script.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"veraedge_firmware","vendor":"getvera"},{"product":"veralite_firmware","vendor":"getvera"}],"cvss":{"score":8.8,"severity":"high","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"}],"description":"An issue was discovered on Vera VeraEdge 1.7.19 and Veralite 1.7.481 devices. The device provides a web user interface that allows a user to manage the device. As a part of the functionality the device firmware file contains a file known as relay.sh which allows the device to create relay ports and connect the device to Vera servers. This is primarily used as a method of communication between the device and Vera servers so the devices can be communicated with even when the user is not at home. One of the parameters retrieved by this specific script is \"remote_host\". This parameter is not sanitized by the script correctly and is passed in a call to \"eval\" to execute another script where remote_host is concatenated to be passed a parameter to the second script. This allows an attacker to escape from the executed command and then execute any commands of his/her choice.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Command injection in n/a","id":"CVE-2017-9384","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2017"},"n_packages":0,"n_references":3,"next":{"headline":"Path traversal in n/a","id":"CVE-2017-9385"},"packages":[],"prev":{"headline":"Server-side request forgery in n/a","id":"CVE-2017-9383"},"products":["n/a"],"published":"2019-06-17","related":[{"cvss_score":9.9,"headline":"Server-side request forgery in n/a","id":"CVE-2017-9383","kev_date_added":null,"published":"2019-06-17"},{"cvss_score":9.8,"headline":"Path traversal in n/a","id":"CVE-2017-9385","kev_date_added":null,"published":"2019-06-17"},{"cvss_score":8.8,"headline":"Cross-site request forgery in n/a","id":"CVE-2017-9381","kev_date_added":null,"published":"2019-06-17"},{"cvss_score":8.8,"headline":"Command injection in n/a","id":"CVE-2017-9388","kev_date_added":null,"published":"2019-06-17"},{"cvss_score":8.8,"headline":"Auth bypass in n/a","id":"CVE-2017-9389","kev_date_added":null,"published":"2019-06-17"},{"cvss_score":8.8,"headline":"Memory corruption in n/a","id":"CVE-2017-9391","kev_date_added":null,"published":"2019-06-17"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"Attackers can execute arbitrary commands on Vera home automation devices via unsanitized input in the relay.sh script.","url":"https://insights.sbomify.com/CVE-2017-9384/"}