{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2017-9481 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-9481 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-9481 is a high-severity missing authorization vulnerability in n/a, published on 31 Jul 2017. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-9481 and fix it if it is affected.\n\nWhat it is: CVE-2017-9481 is a high-severity missing authorization vulnerability in n/a, published on 31 Jul 2017. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-9481 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-9481/ (Markdown: https://insights.sbomify.com/CVE-2017-9481/index.md)","id":"CVE-2017-9481","markdown":"https://insights.sbomify.com/CVE-2017-9481/index.md","name":"CVE-2017-9481","record":{"aliases":["GHSA-jr56-p22g-v622"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["data_read","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Cisco Cable Modem","requires_auth":"none","summary":"Remote attackers can access the internal Network Processor by adding a specific routing table entry, bypassing intended network isolation.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"dpc3939_firmware","vendor":"cisco"}],"cvss":{"score":7.5,"severity":"high","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N","version":"3.0"},"cwes":[],"description":"The Comcast firmware on Cisco DPC3939 (firmware version dpc3939-P20-18-v303r20421746-170221a-CMCST) devices allows remote attackers to obtain unintended access to the Network Processor (NP) 169.254/16 IP network by adding a routing-table entry that specifies the LAN IP address as the router for that network.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authorization in n/a","id":"CVE-2017-9481","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2017"},"n_packages":0,"n_references":1,"next":{"headline":"Auth bypass in n/a","id":"CVE-2017-9482"},"packages":[],"prev":{"headline":"Information disclosure in n/a","id":"CVE-2017-9480"},"products":["n/a"],"published":"2017-07-31","related":[{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2017-9479","kev_date_added":null,"published":"2017-07-31"},{"cvss_score":9.8,"headline":"Auth bypass in n/a","id":"CVE-2017-9482","kev_date_added":null,"published":"2017-07-31"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2017-9483","kev_date_added":null,"published":"2017-07-31"},{"cvss_score":9.8,"headline":"Other in n/a","id":"CVE-2017-9521","kev_date_added":null,"published":"2017-07-31"},{"cvss_score":8.8,"headline":"Hardcoded credentials in n/a","id":"CVE-2017-9488","kev_date_added":null,"published":"2017-07-31"},{"cvss_score":7.5,"headline":"Information disclosure in n/a","id":"CVE-2017-9478","kev_date_added":null,"published":"2017-07-31"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"Remote attackers can access the internal Network Processor by adding a specific routing table entry, bypassing intended network isolation.","url":"https://insights.sbomify.com/CVE-2017-9481/"}