{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2017-9635 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-9635 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-9635 is a low-severity vulnerability in Schneider Electric SE Ampla MES, published on 18 May 2018. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-9635 and fix it if it is affected.\n\nWhat it is: CVE-2017-9635 is a low-severity vulnerability in Schneider Electric SE Ampla MES, published on 18 May 2018. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-9635 in the wild and no public exploit code.\n\nAffected product: Schneider Electric SE Ampla MES. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-9635/ (Markdown: https://insights.sbomify.com/CVE-2017-9635/index.md)","id":"CVE-2017-9635","markdown":"https://insights.sbomify.com/CVE-2017-9635/index.md","name":"CVE-2017-9635","record":{"aliases":["GHSA-cfpr-7wg7-7x58"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["account_takeover"],"network_reachable":"adjacent_or_local","non_default_config":true,"product_category":"Schneider Electric Ampla MES","requires_auth":"high_privilege","summary":"Weak password hashing in Ampla MES allows attackers to reverse user passwords when Simple Security is enabled, leading to account takeover.","user_interaction":"not_required","vuln_class":"weak_cryptography"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"ampla_manufacturing_execution_system","vendor":"schneider-electric"}],"cvss":{"score":3.9,"severity":"low","source":"nvd","vector":"CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:L","version":"3.0"},"cwes":[{"id":"CWE-326","name":"Inadequate Encryption Strength"}],"description":"Schneider Electric Ampla MES 6.4 provides capability to configure users and their privileges. When Ampla MES users are configured to use Simple Security, a weakness in the password hashing algorithm could be exploited to reverse the user's password. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Weak cryptography in Ampla MES","id":"CVE-2017-9635","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"weak_cryptography","year":"2017"},"n_packages":0,"n_references":3,"next":{"headline":"Memory corruption in E-Designer","id":"CVE-2017-9636"},"packages":[],"prev":{"headline":"Memory corruption in E-Designer","id":"CVE-2017-9634"},"products":["Ampla MES"],"published":"2018-05-18","related":[{"cvss_score":4.1,"headline":"Information disclosure in Ampla MES","id":"CVE-2017-9637","kev_date_added":null,"published":"2018-05-18"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-17","vendors":["Schneider Electric SE"]},"summary":"Weak password hashing in Ampla MES allows attackers to reverse user passwords when Simple Security is enabled, leading to account takeover.","url":"https://insights.sbomify.com/CVE-2017-9635/"}