{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2017-9944 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2017-9944 yet. Limit exposure of the affected software until one is available.","what":"CVE-2017-9944 is a critical authentication bypass vulnerability in Siemens 7KT PAC1200 data manager (7KT1260) All versions \u003c V2.03, published on 26 Dec 2017. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2017-9944 and fix it if it is affected.\n\nWhat it is: CVE-2017-9944 is a critical authentication bypass vulnerability in Siemens 7KT PAC1200 data manager (7KT1260) All versions \u003c V2.03, published on 26 Dec 2017. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2017-9944 in the wild and no public exploit code.\n\nAffected product: Siemens 7KT PAC1200 data manager (7KT1260) All versions \u003c V2.03. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2017-9944/ (Markdown: https://insights.sbomify.com/CVE-2017-9944/index.md)","id":"CVE-2017-9944","markdown":"https://insights.sbomify.com/CVE-2017-9944/index.md","name":"CVE-2017-9944","record":{"aliases":["GHSA-3rg5-wjqj-4q4g"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["privilege_escalation","code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens data manager","requires_auth":"none","summary":"Unauthenticated remote attackers can perform administrative operations on Siemens 7KT PAC1200 devices via the integrated web server.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"7kt_pac1200_data_manager_firmware","vendor":"siemens"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-269","name":"Improper Privilege Management"},{"id":"CWE-288","name":"Authentication Bypass Using an Alternate Path or Channel"}],"description":"A vulnerability has been identified in Siemens 7KT PAC1200 data manager (7KT1260) in all versions \u003c V2.03. The integrated web server (port 80/tcp) of the affected devices could allow an unauthenticated remote attacker to perform administrative operations over the network.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Auth bypass in Siemens 7KT PAC1200 data manager (7KT1260) All versions \u003c V2.03","id":"CVE-2017-9944","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2017"},"n_packages":0,"n_references":2,"next":{"headline":"In the Siemens 7KM PAC Switched Ethernet PROFINET expansion module (All versions \u003c V2.1.3), a Denial-of-Service condition could be induced b","id":"CVE-2017-9945"},"packages":[],"prev":{"headline":"Information disclosure in SiPass integrated All versions before V2.70","id":"CVE-2017-9942"},"products":["Siemens 7KT PAC1200 data manager (7KT1260) All versions \u003c V2.03"],"published":"2017-12-26","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"Unauthenticated remote attackers can perform administrative operations on Siemens 7KT PAC1200 devices via the integrated web server.","url":"https://insights.sbomify.com/CVE-2017-9944/"}