{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2018-0049 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-0049 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-0049 is a high-severity vulnerability in Juniper Junos, published on 10 Oct 2018. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-0049 and fix it if it is affected.\n\nWhat it is: CVE-2018-0049 is a high-severity vulnerability in Juniper Junos, published on 10 Oct 2018. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-0049 in the wild and no public exploit code.\n\nAffected product: Juniper Junos. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-0049/ (Markdown: https://insights.sbomify.com/CVE-2018-0049/index.md)","id":"CVE-2018-0049","markdown":"https://insights.sbomify.com/CVE-2018-0049/index.md","name":"CVE-2018-0049","record":{"aliases":["GHSA-cvg4-hp78-jhgv"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["denial_of_service"],"network_reachable":"yes","non_default_config":true,"product_category":"Juniper Junos OS","requires_auth":"none","summary":"An attacker can crash the Junos OS kernel by sending crafted MPLS packets to interfaces configured for such traffic, causing a denial of service.","user_interaction":"not_required","vuln_class":"null_dereference"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"juniper","cpe":[{"product":"junos","vendor":"juniper"}],"cvss":{"score":7.5,"severity":"high","source":"cna","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.0"},"cwes":[{"id":"CWE-476","name":"NULL Pointer Dereference"}],"description":"A NULL Pointer Dereference vulnerability in Juniper Networks Junos OS allows an attacker to cause the Junos OS kernel to crash. Continued receipt of this specifically crafted malicious MPLS packet will cause a sustained Denial of Service condition. This issue require it to be received on an interface configured to receive this type of traffic. Affected releases are Juniper Networks Junos OS: 12.1X46 versions above and including 12.1X46-D76 prior to 12.1X46-D81 on SRX100, SRX110, SRX210, SRX220, SRX240m, SRX550m SRX650, SRX300, SRX320, SRX340, SRX345, SRX1500, SRX4100, SRX4200, SRX4600 and vSRX; 12.3R12-S10; 12.3X48 versions above and including 12.3X48-D66 prior to 12.3X48-D75 on SRX100, SRX110, SRX210, SRX220, SRX240m, SRX550m SRX650, SRX300, SRX320, SRX340, SRX345, SRX1500, SRX4100, SRX4200, SRX4600 and vSRX; 14.1X53-D47 on EX2200/VC, EX3200, EX3300/VC, EX4200, EX4300, EX4550/VC, EX4600, EX6200, EX8200/VC (XRE), QFX3500, QFX3600, QFX5100; 14.1X53 versions above and including 14.1X53-D115 prior to 14.1X53-D130 on QFabric System; 15.1 versions above and including 15.1F6-S10; 15.1R4-S9; 15.1R6-S6; 15.1 versions above and including 15.1R7 prior to 15.1R7-S2; 15.1X49 versions above and including 15.1X49-D131 prior to 15.1X49-D150 on SRX100, SRX110, SRX210, SRX220, SRX240m, SRX550m SRX650, SRX300, SRX320, SRX340, SRX345, SRX1500, SRX4100, SRX4200, SRX4600 and vSRX; 15.1X53 versions above 15.1X53-D233 prior to 15.1X53-D235 on QFX5200/QFX5110; 15.1X53 versions up to and including 15.1X53-D471 prior to 15.1X53-D590 on NFX150, NFX250; 15.1X53-D67 on QFX10000 Series; 15.1X53-D59 on EX2300/EX3400; 16.1 versions above and including 16.1R3-S8; 16.1 versions above and including 16.1R4-S9 prior to 16.1R4-S12; 16.1 versions above and including 16.1R5-S4; 16.1 versions above and including 16.1R6-S3 prior to 16.1R6-S6; 16.1 versions above and including 16.1R7 prior to 16.1R7-S2; 16.2 versions above and including 16.2R1-S6; 16.2 versions above and including 16.2R2-S5 prior to 16.2R2-S7; 17.1R1-S7; 17.1 versions above and including 17.1R2-S7 prior to 17.1R2-S9; 17.2R1-S6; 17.2 versions above and including 17.2R2-S4 prior to 17.2R2-S6; 17.2X75 versions above and including 17.2X75-D100 prior to X17.2X75-D101, 17.2X75-D110; 17.3 versions above and including 17.3R1-S4 on All non-SRX Series and SRX100, SRX110, SRX210, SRX220, SRX240m, SRX550m SRX650, SRX300, SRX320, SRX340, SRX345, SRX1500, SRX4100, SRX4200, SRX4600 and vSRX; 17.3 versions above and including 17.3R2-S2 prior to 17.3R2-S4 on All non-SRX Series and SRX100, SRX110, SRX210, SRX220, SRX240m, SRX550m SRX650, SRX300, SRX320, SRX340, SRX345, SRX1500, SRX4100, SRX4200, SRX4600 and vSRX; 17.3R3 on All non-SRX Series and SRX100, SRX110, SRX210, SRX220, SRX240m, SRX550m SRX650, SRX300, SRX320, SRX340, SRX345, SRX1500, SRX4100, SRX4200, SRX4600 and vSRX; 17.4 versions above and including 17.4R1-S3 prior to 17.4R1-S5 on All non-SRX Series and SRX100, SRX110, SRX210, SRX220, SRX240m, SRX550m SRX650, SRX300, SRX320, SRX340, SRX345, SRX1500, SRX4100, SRX4200, SRX4600 and vSRX; 17.4R2 on All non-SRX Series and SRX100, SRX110, SRX210, SRX220, SRX240m, SRX550m SRX650, SRX300, SRX320, SRX340, SRX345, SRX1500, SRX4100, SRX4200, SRX4600 and vSRX; 18.1 versions above and including 18.1R2 prior to 18.1R2-S3, 18.1R3 on All non-SRX Series and SRX100, SRX110, SRX210, SRX220, SRX240m, SRX550m SRX650, SRX300, SRX320, SRX340, SRX345, SRX1500, SRX4100, SRX4200, SRX4600 and vSRX; 18.2 versions above and including 18.2R1 prior to 18.2R1-S2, 18.2R1-S3, 18.2R2 on All non-SRX Series and SRX100, SRX110, SRX210, SRX220, SRX240m, SRX550m SRX650, SRX300, SRX320, SRX340, SRX345, SRX1500, SRX4100, SRX4200, SRX4600 and vSRX; 18.2X75 versions above and including 18.2X75-D5 prior to 18.2X75-D20.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Junos OS: Receipt of a specifically crafted malicious MPLS packet leads to a Junos kernel crash.","id":"CVE-2018-0049","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"juniper:junos","products":["juniper:junos"],"type":"null_dereference","year":"2018"},"n_packages":0,"n_references":4,"next":{"headline":"Junos OS: Receipt of a malformed MPLS RSVP packet leads to a Routing Protocols Daemon (RPD) crash.","id":"CVE-2018-0050"},"packages":[],"prev":{"headline":"Denial of service in Junos OS","id":"CVE-2018-0048"},"products":["Junos OS"],"published":"2018-10-10","related":[{"cvss_score":9.8,"headline":"Juniper Junos OS EX Series and SRX Series PHP External Variable Modification","id":"CVE-2023-36845","kev_date_added":"2023-11-13","published":"2023-08-17"},{"cvss_score":8.8,"headline":"Juniper Junos OS Path Traversal","id":"CVE-2020-1631","kev_date_added":"2022-03-25","published":"2020-05-04"},{"cvss_score":6.7,"headline":"Juniper Junos OS Improper Isolation or Compartmentalization","id":"CVE-2025-21590","kev_date_added":"2025-03-13","published":"2025-03-12"},{"cvss_score":5.3,"headline":"Juniper Junos OS SRX Series Missing Authentication for Critical Function","id":"CVE-2023-36851","kev_date_added":"2023-11-13","published":"2023-09-26"},{"cvss_score":5.3,"headline":"Juniper Junos OS EX Series PHP External Variable Modification","id":"CVE-2023-36844","kev_date_added":"2023-11-13","published":"2023-08-17"},{"cvss_score":5.3,"headline":"Juniper Junos OS SRX Series Missing Authentication for Critical Function","id":"CVE-2023-36846","kev_date_added":"2023-11-13","published":"2023-08-17"},{"cvss_score":5.3,"headline":"Juniper Junos OS EX Series Missing Authentication for Critical Function","id":"CVE-2023-36847","kev_date_added":"2023-11-13","published":"2023-08-17"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-17","vendors":["Juniper Networks"]},"summary":"An attacker can crash the Junos OS kernel by sending crafted MPLS packets to interfaces configured for such traffic, causing a denial of service.","url":"https://insights.sbomify.com/CVE-2018-0049/"}