{"answers":{"affected":"It affects 18 products.","exploited":"There is no known exploitation of CVE-2018-10599 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-10599 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-10599 is a medium-severity vulnerability in ICS-CERT IntelliVue Patient Monitors, Avalon Fetal/Maternal Monitors, published on 5 Jun 2018. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-10599 and fix it if it is affected.\n\nWhat it is: CVE-2018-10599 is a medium-severity vulnerability in ICS-CERT IntelliVue Patient Monitors, Avalon Fetal/Maternal Monitors, published on 5 Jun 2018. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-10599 in the wild and no public exploit code.\n\nAffected product: ICS-CERT IntelliVue Patient Monitors, Avalon Fetal/Maternal Monitors. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-10599/ (Markdown: https://insights.sbomify.com/CVE-2018-10599/index.md)","id":"CVE-2018-10599","markdown":"https://insights.sbomify.com/CVE-2018-10599/index.md","name":"CVE-2018-10599","record":{"aliases":["GHSA-36x7-j8mh-46ff"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Medical patient monitors","requires_auth":"none","summary":"An unauthenticated attacker on the same subnet can read arbitrary memory from vulnerable Philips patient monitors, potentially exposing sensitive data.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"avalon_fetal\\/maternal_monitors_fm20_firmware","vendor":"philips"},{"product":"avalon_fetal\\/maternal_monitors_fm30_firmware","vendor":"philips"},{"product":"avalon_fetal\\/maternal_monitors_fm40_firmware","vendor":"philips"},{"product":"avalon_fetal\\/maternal_monitors_fm50_firmware","vendor":"philips"},{"product":"intellivue_mp2_firmware","vendor":"philips"},{"product":"intellivue_mp30_firmware","vendor":"philips"},{"product":"intellivue_mp50_firmware","vendor":"philips"},{"product":"intellivue_mp70_firmware","vendor":"philips"},{"product":"intellivue_mx100_firmware","vendor":"philips"},{"product":"intellivue_mx400_firmware","vendor":"philips"},{"product":"intellivue_mx450_firmware","vendor":"philips"},{"product":"intellivue_mx500_firmware","vendor":"philips"},{"product":"intellivue_mx550_firmware","vendor":"philips"},{"product":"intellivue_mx700_firmware","vendor":"philips"},{"product":"intellivue_mx800_firmware","vendor":"philips"},{"product":"intellivue_np90_firmware","vendor":"philips"},{"product":"intellivue_x2_firmware","vendor":"philips"},{"product":"intellivue_x3_firmware","vendor":"philips"}],"cvss":{"score":5.3,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.0"},"cwes":[{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to read memory from an attacker-chosen device address within the same subnet.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in IntelliVue Patient Monitors, Avalon Fetal/Maternal Monitors","id":"CVE-2018-10599","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2018"},"n_packages":0,"n_references":1,"next":{"headline":"XML external entity in AcSELerator Architect","id":"CVE-2018-10600"},"packages":[],"prev":{"headline":"Memory corruption in CNCSoft with ScreenEditor","id":"CVE-2018-10598"},"products":["IntelliVue Patient Monitors, Avalon Fetal/Maternal Monitors"],"published":"2018-06-05","related":[{"cvss_score":8.3,"headline":"Memory corruption in IntelliVue Patient Monitors, Avalon Fetal/Maternal Monitors","id":"CVE-2018-10597","kev_date_added":null,"published":"2018-06-05"},{"cvss_score":8.2,"headline":"Memory corruption in IntelliVue Patient Monitors, Avalon Fetal/Maternal Monitors","id":"CVE-2018-10601","kev_date_added":null,"published":"2018-06-05"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-16","vendors":["ICS-CERT"]},"summary":"An unauthenticated attacker on the same subnet can read arbitrary memory from vulnerable Philips patient monitors, potentially exposing sensitive data.","url":"https://insights.sbomify.com/CVE-2018-10599/"}