{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2018-10611 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-10611 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-10611 is a critical authentication bypass vulnerability in GE MDS PulseNET and MDS PulseNET Enterprise, published on 4 Jun 2018. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-10611 and fix it if it is affected.\n\nWhat it is: CVE-2018-10611 is a critical authentication bypass vulnerability in GE MDS PulseNET and MDS PulseNET Enterprise, published on 4 Jun 2018. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-10611 in the wild and no public exploit code.\n\nAffected product: GE MDS PulseNET and MDS PulseNET Enterprise. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-10611/ (Markdown: https://insights.sbomify.com/CVE-2018-10611/index.md)","id":"CVE-2018-10611","markdown":"https://insights.sbomify.com/CVE-2018-10611/index.md","name":"CVE-2018-10611","record":{"aliases":["GHSA-phjq-8f4h-vmmv"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["code_execution","privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"GE MDS PulseNET","requires_auth":"none","summary":"Unauthenticated attackers can exploit the Java RMI input port to launch applications and execute remote code on GE MDS PulseNET systems.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"mds_pulsenet","vendor":"ge"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-287","name":"Improper Authentication"}],"description":"Java remote method invocation (RMI) input port in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior may be exploited to allow unauthenticated users to launch applications and support remote code execution through web services.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Auth bypass in MDS PulseNET and MDS PulseNET Enterprise","id":"CVE-2018-10611","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2018"},"n_packages":0,"n_references":3,"next":{"headline":"Misconfiguration in 3S-Smart Software Solutions GmbH CODESYS Control V3 products prior to version 3.5.14.0","id":"CVE-2018-10612"},"packages":[],"prev":{"headline":"Memory corruption in LeviStudioU","id":"CVE-2018-10610"},"products":["MDS PulseNET and MDS PulseNET Enterprise"],"published":"2018-06-04","related":[{"cvss_score":10,"headline":"Path traversal in n/a","id":"CVE-2015-6459","kev_date_added":null,"published":"2015-09-18"},{"cvss_score":9,"headline":"Hardcoded credentials in n/a","id":"CVE-2015-6456","kev_date_added":null,"published":"2015-09-18"},{"cvss_score":8.1,"headline":"Path traversal in MDS PulseNET and MDS PulseNET Enterprise","id":"CVE-2018-10615","kev_date_added":null,"published":"2018-06-04"},{"cvss_score":7.5,"headline":"XML external entity in MDS PulseNET and MDS PulseNET Enterprise","id":"CVE-2018-10613","kev_date_added":null,"published":"2018-06-04"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-16","vendors":["GE"]},"summary":"Unauthenticated attackers can exploit the Java RMI input port to launch applications and execute remote code on GE MDS PulseNET systems.","url":"https://insights.sbomify.com/CVE-2018-10611/"}