{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2018-10622 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-10622 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-10622 is a medium-severity vulnerability in Medtronic 24950 MyCareLink Monitor, published on 10 Aug 2018. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-10622 and fix it if it is affected.\n\nWhat it is: CVE-2018-10622 is a medium-severity vulnerability in Medtronic 24950 MyCareLink Monitor, published on 10 Aug 2018. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-10622 in the wild and no public exploit code.\n\nAffected product: Medtronic 24950 MyCareLink Monitor. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-10622/ (Markdown: https://insights.sbomify.com/CVE-2018-10622/index.md)","id":"CVE-2018-10622","markdown":"https://insights.sbomify.com/CVE-2018-10622/index.md","name":"CVE-2018-10622","record":{"aliases":["GHSA-h42x-qcjr-3ww7"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["security_bypass","account_takeover"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Medtronic patient monitor","requires_auth":"none","summary":"Attackers can recover stored network credentials from Medtronic MyCareLink monitors to bypass authentication and gain unauthorized access.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"mycarelink_24950_patient_monitor_firmware","vendor":"medtronic"},{"product":"mycarelink_24952_patient_monitor_firmware","vendor":"medtronic"}],"cvss":{"score":5.2,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:N","version":"3.1"},"cwes":[{"id":"CWE-522","name":"Insufficiently Protected Credentials"},{"id":"CWE-313","name":"Cleartext Storage in a File or on Disk"}],"description":"Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Medtronic MyCareLink Patient Monitor Network Credential Weakness","id":"CVE-2018-10622","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2018"},"n_packages":0,"n_references":4,"next":{"headline":"Memory corruption in Delta Industrial Automation DOPSoft","id":"CVE-2018-10623"},"packages":[],"prev":{"headline":"Memory corruption in Delta Industrial Automation DOPSoft","id":"CVE-2018-10621"},"products":["24950 MyCareLink Monitor","24952 MyCareLink Monitor"],"published":"2018-08-10","related":[{"cvss_score":4.4,"headline":"Medtronic MyCareLink 24950 Patient Monitor Insufficient Verification of Data Authenticity","id":"CVE-2018-10626","kev_date_added":null,"published":"2018-08-10"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2026-06-22","vendors":["Medtronic"]},"summary":"Attackers can recover stored network credentials from Medtronic MyCareLink monitors to bypass authentication and gain unauthorized access.","url":"https://insights.sbomify.com/CVE-2018-10622/"}