{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2018-10624 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-10624 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-10624 is a medium-severity vulnerability in Johnson Controls BCPro (BCM), published on 1 Aug 2018. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-10624 and fix it if it is affected.\n\nWhat it is: CVE-2018-10624 is a medium-severity vulnerability in Johnson Controls BCPro (BCM), published on 1 Aug 2018. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-10624 in the wild and no public exploit code.\n\nAffected product: Johnson Controls BCPro (BCM). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-10624/ (Markdown: https://insights.sbomify.com/CVE-2018-10624/index.md)","id":"CVE-2018-10624","markdown":"https://insights.sbomify.com/CVE-2018-10624/index.md","name":"CVE-2018-10624","record":{"aliases":["GHSA-6ph9-8g4v-9g63"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Building automation system","requires_auth":"none","summary":"Attackers can obtain sensitive technical information via improper error handling in HTTP communications, affecting Johnson Controls Metasys and BCPro systems.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"bcpro","vendor":"johnsoncontrols"},{"product":"metasys_system","vendor":"johnsoncontrols"}],"cvss":{"score":4.3,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-388","name":null},{"id":"CWE-209","name":"Generation of Error Message Containing Sensitive Information"}],"description":"In Johnson Controls Metasys System Versions 8.0 and prior and BCPro (BCM) all versions prior to 3.0.2, this vulnerability results from improper error handling in HTTP-based communications with the server, which could allow an attacker to obtain technical information.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Johnson Controls Metasys and BCPro Generation of Error Message Containing Sensitive Information","id":"CVE-2018-10624","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2018"},"n_packages":0,"n_references":2,"next":{"headline":"Medtronic MyCareLink 24950 Patient Monitor Insufficient Verification of Data Authenticity","id":"CVE-2018-10626"},"packages":[],"prev":{"headline":"Memory corruption in Delta Industrial Automation DOPSoft","id":"CVE-2018-10623"},"products":["BCPro (BCM)","Metasys System"],"published":"2018-08-01","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2026-09-10","vendors":["Johnson Controls"]},"summary":"Attackers can obtain sensitive technical information via improper error handling in HTTP communications, affecting Johnson Controls Metasys and BCPro systems.","url":"https://insights.sbomify.com/CVE-2018-10624/"}