{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2018-10626 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-10626 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-10626 is a medium-severity vulnerability in Medtronic 24950 MyCareLink Monitor, published on 10 Aug 2018. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-10626 and fix it if it is affected.\n\nWhat it is: CVE-2018-10626 is a medium-severity vulnerability in Medtronic 24950 MyCareLink Monitor, published on 10 Aug 2018. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-10626 in the wild and no public exploit code.\n\nAffected product: Medtronic 24950 MyCareLink Monitor. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-10626/ (Markdown: https://insights.sbomify.com/CVE-2018-10626/index.md)","id":"CVE-2018-10626","markdown":"https://insights.sbomify.com/CVE-2018-10626/index.md","name":"CVE-2018-10626","record":{"aliases":["GHSA-gf7p-63p6-4m97"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["data_modify"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Cardiac patient monitor","requires_auth":"low_privilege","summary":"An attacker with device credentials can upload invalid data to the Medtronic CareLink network due to insufficient data authenticity verification.","user_interaction":"not_required","vuln_class":"other"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"mycarelink_24950_patient_monitor_firmware","vendor":"medtronic"},{"product":"mycarelink_24952_patient_monitor_firmware","vendor":"medtronic"}],"cvss":{"score":4.4,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:N","version":"3.1"},"cwes":[{"id":"CWE-345","name":"Insufficient Verification of Data Authenticity"}],"description":"Medtronic MyCareLink Patient Monitor’s update service does not sufficiently verify the authenticity of the data uploaded. An \nattacker who obtains per-product credentials from the monitor and paired\n implantable cardiac device information can potentially upload invalid \ndata to the Medtronic CareLink network.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Medtronic MyCareLink 24950 Patient Monitor Insufficient Verification of Data Authenticity","id":"CVE-2018-10626","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"other","year":"2018"},"n_packages":0,"n_references":4,"next":{"headline":"Information disclosure in SmartServer 1","id":"CVE-2018-10627"},"packages":[],"prev":{"headline":"Johnson Controls Metasys and BCPro Generation of Error Message Containing Sensitive Information","id":"CVE-2018-10624"},"products":["24950 MyCareLink Monitor","24952 MyCareLink Monitor"],"published":"2018-08-10","related":[{"cvss_score":5.2,"headline":"Medtronic MyCareLink Patient Monitor Network Credential Weakness","id":"CVE-2018-10622","kev_date_added":null,"published":"2018-08-10"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2026-05-19","vendors":["Medtronic"]},"summary":"An attacker with device credentials can upload invalid data to the Medtronic CareLink network due to insufficient data authenticity verification.","url":"https://insights.sbomify.com/CVE-2018-10626/"}