{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2018-10631 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-10631 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-10631 is a medium-severity vulnerability in Medtronic 8840 N’Vision Clinician Programmer, published on 13 Jul 2018. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2018-10631 and fix it if it is affected.\n\nWhat it is: CVE-2018-10631 is a medium-severity vulnerability in Medtronic 8840 N’Vision Clinician Programmer, published on 13 Jul 2018. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2018-10631 in the wild and no public exploit code.\n\nAffected product: Medtronic 8840 N’Vision Clinician Programmer. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-10631/ (Markdown: https://insights.sbomify.com/CVE-2018-10631/index.md)","id":"CVE-2018-10631","markdown":"https://insights.sbomify.com/CVE-2018-10631/index.md","name":"CVE-2018-10631","record":{"aliases":["GHSA-4g99-xhm8-2rwc"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["code_execution","privilege_escalation"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Medtronic Clinician Programmer","requires_auth":"none","summary":"Attackers with physical access can modify application card binaries to bypass protection mechanisms and execute malicious code on the programmer.","user_interaction":"required","vuln_class":"security_feature_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"n\\'vision_8840_firmware","vendor":"medtronic"},{"product":"n\\'vision_8870_firmware","vendor":"medtronic"}],"cvss":{"score":6.3,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:P/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-693","name":"Protection Mechanism Failure"}],"description":"The 8840 Clinician Programmer executes the application program from the 8870 Application Card. An attacker with physical access to an 8870 Application Card and sufficient technical capability can modify the contents of this card, including the binary executables. If modified to bypass protection mechanisms, this malicious code will be run when the card is inserted into an 8840 Clinician Programmer.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Medtronic N'Vision Clinician Programmer Protection Mechanism Failure","id":"CVE-2018-10631","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"security_feature_bypass","year":"2018"},"n_packages":0,"n_references":4,"next":{"headline":"Denial of service in NPort 5210, 5230, and 5232","id":"CVE-2018-10632"},"packages":[],"prev":{"headline":"Auth bypass in Crestron TSW-X60 version prior to 2.001.0037.001 and MC3 version prior to 1.502.0047.001","id":"CVE-2018-10630"},"products":["8840 N’Vision Clinician Programmer","8870 N’Vision removable Application Card"],"published":"2018-07-13","related":[{"cvss_score":4.6,"headline":"Medtronic N'Vision Clinician Programmer Missing Encryption of Sensitive Data","id":"CVE-2018-8849","kev_date_added":null,"published":"2018-05-18"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-08-26","vendors":["Medtronic"]},"summary":"Attackers with physical access can modify application card binaries to bypass protection mechanisms and execute malicious code on the programmer.","url":"https://insights.sbomify.com/CVE-2018-10631/"}