{"answers":{"affected":"It affects 9 products.","exploited":"There is no known exploitation of CVE-2018-10634 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-10634 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-10634 is a medium-severity vulnerability in Medtronic MMT – 511 pump Paradigm, published on 13 Aug 2018. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2018-10634 and fix it if it is affected.\n\nWhat it is: CVE-2018-10634 is a medium-severity vulnerability in Medtronic MMT – 511 pump Paradigm, published on 13 Aug 2018. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2018-10634 in the wild and no public exploit code.\n\nAffected product: Medtronic MMT – 511 pump Paradigm. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-10634/ (Markdown: https://insights.sbomify.com/CVE-2018-10634/index.md)","id":"CVE-2018-10634","markdown":"https://insights.sbomify.com/CVE-2018-10634/index.md","name":"CVE-2018-10634","record":{"aliases":["GHSA-fxw8-j27m-3752"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Medtronic insulin pump","requires_auth":"none","summary":"Attackers can capture cleartext wireless communications from Medtronic MiniMed pumps to extract sensitive device information like serial numbers.","user_interaction":"required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"minimed_530g_mmt-551_firmware","vendor":"medtronic"},{"product":"minimed_530g_mmt-751_firmware","vendor":"medtronic"},{"product":"minimed_paradigm_508_insulin_pump_firmware","vendor":"medtronic"},{"product":"minimed_paradigm_real-time_mmt-522_firmware","vendor":"medtronic"},{"product":"minimed_paradigm_real-time_mmt-722_firmware","vendor":"medtronic"},{"product":"minimed_paradigm_revel_mmt-523_firmware","vendor":"medtronic"},{"product":"minimed_paradigm_revel_mmt-523k_firmware","vendor":"medtronic"},{"product":"minimed_paradigm_revel_mmt-723_firmware","vendor":"medtronic"},{"product":"minimed_paradigm_revel_mmt-723k_firmware","vendor":"medtronic"}],"cvss":{"score":4.8,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-319","name":"Cleartext Transmission of Sensitive Information"}],"description":"Communications between Medtronic MiniMed MMT pumps and wireless accessories are transmitted in cleartext. A sufficiently skilled attacker could capture these transmissions and extract sensitive information, such as device serial numbers.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Medtronic MiniMed MMT-500/MMT-503 Remote Controllers Cleartext Transmission of Sensitive Information","id":"CVE-2018-10634","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2018"},"n_packages":0,"n_references":3,"next":{"headline":"Code injection in Universal Robots Robot Controllers Version CB 3.1, SW Version 3.4.5-100","id":"CVE-2018-10635"},"packages":[],"prev":{"headline":"Hardcoded credentials in Universal Robots Robot Controller version CB 3.1, SW Version 3.4.5-100","id":"CVE-2018-10633"},"products":["MMT – 511 pump Paradigm","MMT – 512 / MMT – 712 Paradigm x12","MMT – 515 / MMT – 715 Paradigm x15","MMT – 522 / MMT – 722 Paradigm REAL-TIME","MMT – 522(K) / MMT – 722(K) Paradigm REAL-TIME","MMT – 523 / MMT – 723 Paradigm Revel","MMT – 523(K) / MMT – 723(K) Paradigm","MMT – 551 / MMT – 751 MiniMed 530G","MMT – 554 / MMT – 754 MiniMed Veo","MMT- 508 - MiniMed pump"],"published":"2018-08-13","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2025-05-22","vendors":["Medtronic"]},"summary":"Attackers can capture cleartext wireless communications from Medtronic MiniMed pumps to extract sensitive device information like serial numbers.","url":"https://insights.sbomify.com/CVE-2018-10634/"}