{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2018-11448 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-11448 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-11448 is a medium-severity cross-site scripting vulnerability in Siemens AG SCALANCE M875, published on 26 Jun 2018. An attacker needs administrator access to exploit it, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2018-11448 and fix it if it is affected.\n\nWhat it is: CVE-2018-11448 is a medium-severity cross-site scripting vulnerability in Siemens AG SCALANCE M875, published on 26 Jun 2018. An attacker needs administrator access to exploit it, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2018-11448 in the wild and no public exploit code.\n\nAffected product: Siemens AG SCALANCE M875. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-11448/ (Markdown: https://insights.sbomify.com/CVE-2018-11448/index.md)","id":"CVE-2018-11448","markdown":"https://insights.sbomify.com/CVE-2018-11448/index.md","name":"CVE-2018-11448","record":{"aliases":["GHSA-g2w7-2wmm-w74m"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens SCALANCE router","requires_auth":"high_privilege","summary":"An authenticated attacker can inject malicious scripts into the web interface, leading to code execution in the browser of legitimate users.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"scalance_m875_firmware","vendor":"siemens"}],"cvss":{"score":4.8,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N","version":"3.0"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"},{"id":"CWE-352","name":"Cross-Site Request Forgery"}],"description":"A vulnerability has been identified in SCALANCE M875 (All versions). The web interface on port 443/tcp could allow a stored Cross-Site Scripting (XSS) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires that the attacker has access to the web interface of an affected device. The attacker must be authenticated as administrative user on the web interface. Afterwards, a legitimate user must access the web interface. A successful attack could allow an attacker to execute malicious code in the browser of a legitimate user. At the time of advisory publication no public exploitation of this security vulnerability was known.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cross-site scripting in SCALANCE M875","id":"CVE-2018-11448","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2018"},"n_packages":0,"n_references":1,"next":{"headline":"Information disclosure in SCALANCE M875","id":"CVE-2018-11449"},"packages":[],"prev":{"headline":"Cross-site request forgery in SCALANCE M875","id":"CVE-2018-11447"},"products":["SCALANCE M875"],"published":"2018-06-26","related":[{"cvss_score":8.8,"headline":"Cross-site request forgery in SCALANCE M875","id":"CVE-2018-11447","kev_date_added":null,"published":"2018-06-26"},{"cvss_score":7.8,"headline":"Information disclosure in SCALANCE M875","id":"CVE-2018-11449","kev_date_added":null,"published":"2018-06-26"},{"cvss_score":7.2,"headline":"Command injection in SCALANCE M875","id":"CVE-2018-4859","kev_date_added":null,"published":"2018-06-26"},{"cvss_score":7.2,"headline":"Command injection in SCALANCE M875","id":"CVE-2018-4860","kev_date_added":null,"published":"2018-06-26"},{"cvss_score":4.9,"headline":"Path traversal in SCALANCE M875","id":"CVE-2018-4861","kev_date_added":null,"published":"2018-06-26"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-16","vendors":["Siemens AG"]},"summary":"An authenticated attacker can inject malicious scripts into the web interface, leading to code execution in the browser of legitimate users.","url":"https://insights.sbomify.com/CVE-2018-11448/"}