{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2018-11691 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-11691 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-11691 is a critical vulnerability in n/a, published on 14 May 2019. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-11691 and fix it if it is affected.\n\nWhat it is: CVE-2018-11691 is a critical vulnerability in n/a, published on 14 May 2019. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-11691 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-11691/ (Markdown: https://insights.sbomify.com/CVE-2018-11691/index.md)","id":"CVE-2018-11691","markdown":"https://insights.sbomify.com/CVE-2018-11691/index.md","name":"CVE-2018-11691","record":{"aliases":["GHSA-jxcc-245j-87v3"],"analysis":{"component_type":"network_device","fix_type":"patch","impacts":["privilege_escalation","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Industrial network switch","requires_auth":"none","summary":"The DeltaV Smart Switch Command Center fails to update management passwords during commissioning, allowing unauthorized access to industrial network switches.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"ve6046_firmware","vendor":"emerson"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-798","name":"Use of Hard-coded Credentials"}],"description":"Emerson DeltaV Smart Switch Command Center application, available in versions 11.3.x and 12.3.1, was unable to change the DeltaV Smart Switches’ management password upon commissioning. Emerson released patches for DeltaV workstations to address this issue, and the patches can be downloaded from Emerson’s Guardian Support Portal. Please refer to the DeltaV Security Notification DSN19003 (KBA NK-1900-0808) for more information about this issue. DeltaV versions 13.3 and higher use the Network Device Command Center application to manage DeltaV Smart Switches, and this newer application is not impacted by this issue. After patching the Smart Switch Command Center, users are required to either commission the DeltaV Smart Switches or change password using the tool.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hardcoded credentials in n/a","id":"CVE-2018-11691","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2018"},"n_packages":0,"n_references":3,"next":{"headline":"Auth bypass in n/a","id":"CVE-2018-11692"},"packages":[],"prev":{"headline":"Cross-site scripting in n/a","id":"CVE-2018-11690"},"products":["n/a"],"published":"2019-05-14","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"The DeltaV Smart Switch Command Center fails to update management passwords during commissioning, allowing unauthorized access to industrial network switches.","url":"https://insights.sbomify.com/CVE-2018-11691/"}