{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2018-1251 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-1251 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-1251 is a high-severity vulnerability in Dell EMC Unity, published on 28 Sep 2018. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2018-1251 and fix it if it is affected.\n\nWhat it is: CVE-2018-1251 is a high-severity vulnerability in Dell EMC Unity, published on 28 Sep 2018. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2018-1251 in the wild and no public exploit code.\n\nAffected product: Dell EMC Unity. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-1251/ (Markdown: https://insights.sbomify.com/CVE-2018-1251/index.md)","id":"CVE-2018-1251","markdown":"https://insights.sbomify.com/CVE-2018-1251/index.md","name":"CVE-2018-1251","record":{"aliases":["GHSA-j958-56r6-475c"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["security_bypass","data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Dell EMC Unity storage","requires_auth":"none","summary":"Remote attackers can redirect Unity users to malicious sites via crafted URLs, potentially phishing credentials from victims.","user_interaction":"required","vuln_class":"open_redirect"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"dell","cpe":[{"product":"emc_unity_firmware","vendor":"dell"},{"product":"emc_unityvsa","vendor":"dell"}],"cvss":{"score":8.3,"severity":"high","source":"cna","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L","version":"3.0"},"cwes":[{"id":"CWE-601","name":"URL Redirection to Untrusted Site"}],"description":"Dell EMC Unity and UnityVSA versions prior to 4.3.1.1525703027 contains a URL Redirection vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability to redirect Unity users to arbitrary web URLs by tricking the victim user to click on a maliciously crafted Unisphere URL. Attacker could potentially phish information, including Unisphere users' credentials, from the victim once they are redirected.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Open redirect in Dell EMC Unity","id":"CVE-2018-1251","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"open_redirect","year":"2018"},"n_packages":0,"n_references":1,"next":{"headline":"RSA Web Threat Detection SQL Injection Vulnerability","id":"CVE-2018-1252"},"packages":[],"prev":{"headline":"Missing authorization in Dell EMC Unity","id":"CVE-2018-1250"},"products":["Dell EMC Unity","Dell EMC UnityVSA"],"published":"2018-09-28","related":[{"cvss_score":6.5,"headline":"Missing authorization in Dell EMC Unity","id":"CVE-2018-1250","kev_date_added":null,"published":"2018-09-28"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-16","vendors":["Dell EMC"]},"summary":"Remote attackers can redirect Unity users to malicious sites via crafted URLs, potentially phishing credentials from victims.","url":"https://insights.sbomify.com/CVE-2018-1251/"}