{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2018-13810 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-13810 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-13810 is a medium-severity vulnerability in Siemens CP 1604, published on 17 Apr 2019. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2018-13810 and fix it if it is affected.\n\nWhat it is: CVE-2018-13810 is a medium-severity vulnerability in Siemens CP 1604, published on 17 Apr 2019. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2018-13810 in the wild and no public exploit code.\n\nAffected product: Siemens CP 1604. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-13810/ (Markdown: https://insights.sbomify.com/CVE-2018-13810/index.md)","id":"CVE-2018-13810","markdown":"https://insights.sbomify.com/CVE-2018-13810/index.md","name":"CVE-2018-13810","record":{"aliases":["GHSA-23g5-r56j-rmx3"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens CP device","requires_auth":"none","summary":"An attacker can trick a legitimate user into performing unauthorized actions on the Siemens CP device web interface via CSRF.","user_interaction":"required","vuln_class":"csrf"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"cp_1604_firmware","vendor":"siemens"},{"product":"cp_1616_firmware","vendor":"siemens"}],"cvss":{"score":6.5,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N","version":"3.0"},"cwes":[{"id":"CWE-352","name":"Cross-Site Request Forgery"}],"description":"A vulnerability has been identified in CP 1604 (All versions), CP 1616 (All versions). The integrated configuration web server of the affected CP devices could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by a legitimate user. A successful attack could allow an attacker to trigger actions via the web interface that the legitimate user is allowed to perform. At the time of advisory publication no public exploitation of this vulnerability was known.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cross-site request forgery in CP 1604","id":"CVE-2018-13810","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"csrf","year":"2018"},"n_packages":0,"n_references":1,"next":{"headline":"Weak cryptography in SIMATIC STEP 7 (TIA Portal)","id":"CVE-2018-13811"},"packages":[],"prev":{"headline":"Cross-site scripting in CP 1604","id":"CVE-2018-13809"},"products":["CP 1604","CP 1616"],"published":"2019-04-17","related":[{"cvss_score":9.1,"headline":"Information disclosure in CP 1604","id":"CVE-2018-13808","kev_date_added":null,"published":"2019-04-17"},{"cvss_score":6.1,"headline":"Cross-site scripting in CP 1604","id":"CVE-2018-13809","kev_date_added":null,"published":"2019-04-17"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["Siemens"]},"summary":"An attacker can trick a legitimate user into performing unauthorized actions on the Siemens CP device web interface via CSRF.","url":"https://insights.sbomify.com/CVE-2018-13810/"}