{"answers":{"affected":"It affects 12 products.","exploited":"There is no known exploitation of CVE-2018-13812 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-13812 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-13812 is a high-severity path traversal vulnerability in Siemens AG SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel), published on 13 Dec 2018. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-13812 and fix it if it is affected.\n\nWhat it is: CVE-2018-13812 is a high-severity path traversal vulnerability in Siemens AG SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel), published on 13 Dec 2018. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-13812 in the wild and no public exploit code.\n\nAffected product: Siemens AG SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-13812/ (Markdown: https://insights.sbomify.com/CVE-2018-13812/index.md)","id":"CVE-2018-13812","markdown":"https://insights.sbomify.com/CVE-2018-13812/index.md","name":"CVE-2018-13812","record":{"aliases":["GHSA-v99p-r9xp-cghh"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens HMI Panels","requires_auth":"none","summary":"An unauthenticated attacker can exploit a directory traversal flaw in the integrated web server to download arbitrary files from Siemens HMI devices.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"simatic_hmi_comfort_outdoor_panels_firmware","vendor":"siemens"},{"product":"simatic_hmi_comfort_panels_firmware","vendor":"siemens"},{"product":"simatic_hmi_ktp_mobile_panels_ktp400f_firmware","vendor":"siemens"},{"product":"simatic_hmi_ktp_mobile_panels_ktp700_firmware","vendor":"siemens"},{"product":"simatic_hmi_ktp_mobile_panels_ktp700f_firmware","vendor":"siemens"},{"product":"simatic_hmi_ktp_mobile_panels_ktp900_firmware","vendor":"siemens"},{"product":"simatic_hmi_ktp_mobile_panels_ktp900f_firmware","vendor":"siemens"},{"product":"simatic_hmi_mp_firmware","vendor":"siemens"},{"product":"simatic_hmi_op_firmware","vendor":"siemens"},{"product":"simatic_hmi_tp_firmware","vendor":"siemens"},{"product":"simatic_wincc_\\(tia_portal\\)","vendor":"siemens"},{"product":"simatic_wincc_runtime","vendor":"siemens"}],"cvss":{"score":7.5,"severity":"high","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.0"},"cwes":[{"id":"CWE-22","name":"Improper Limitation of a Pathname to a Restricted Directory"}],"description":"A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions \u003c V15 Update 4), SIMATIC WinCC Runtime Professional (All versions \u003c V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions \u003c V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authentication is required to exploit the vulnerability. The vulnerability impacts the confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Path traversal in SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)","id":"CVE-2018-13812","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2018"},"n_packages":0,"n_references":2,"next":{"headline":"Open redirect in SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)","id":"CVE-2018-13813"},"packages":[],"prev":{"headline":"Weak cryptography in SIMATIC STEP 7 (TIA Portal)","id":"CVE-2018-13811"},"products":["SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)"],"published":"2018-12-13","related":[{"cvss_score":9.1,"headline":"Hardcoded credentials in SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)","id":"CVE-2019-6572","kev_date_added":null,"published":"2019-05-14"},{"cvss_score":8.8,"headline":"Other in SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)","id":"CVE-2018-13814","kev_date_added":null,"published":"2018-12-13"},{"cvss_score":8.1,"headline":"Open redirect in SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)","id":"CVE-2018-13813","kev_date_added":null,"published":"2018-12-13"},{"cvss_score":6.5,"headline":"Weak cryptography in SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)","id":"CVE-2019-6576","kev_date_added":null,"published":"2019-05-14"},{"cvss_score":5.4,"headline":"Cross-site scripting in SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)","id":"CVE-2019-6577","kev_date_added":null,"published":"2019-05-14"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["Siemens AG"]},"summary":"An unauthenticated attacker can exploit a directory traversal flaw in the integrated web server to download arbitrary files from Siemens HMI devices.","url":"https://insights.sbomify.com/CVE-2018-13812/"}