{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2018-14579 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2018-14579 yet. Limit exposure of the affected software until one is available.","what":"CVE-2018-14579 is a critical code injection vulnerability in n/a, published on 24 Jul 2018. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2018-14579 and fix it if it is affected.\n\nWhat it is: CVE-2018-14579 is a critical code injection vulnerability in n/a, published on 24 Jul 2018. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2018-14579 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2018-14579/ (Markdown: https://insights.sbomify.com/CVE-2018-14579/index.md)","id":"CVE-2018-14579","markdown":"https://insights.sbomify.com/CVE-2018-14579/index.md","name":"CVE-2018-14579","record":{"aliases":["GHSA-3345-gfqq-q77j"],"analysis":{"component_type":"web_application","fix_type":"configuration_change","impacts":["code_execution","data_read"],"network_reachable":"yes","non_default_config":true,"product_category":"GolemCMS","requires_auth":"none","summary":"Attackers can execute arbitrary PHP code or read sensitive data if the install directory is left active after installation.","user_interaction":"not_required","vuln_class":"code_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"golemcms","vendor":"golemcms_project"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-94","name":"Improper Control of Generation of Code"}],"description":"GolemCMS through 2008-12-24, if the install/ directory remains active after an installation, allows remote attackers to execute arbitrary PHP code by inserting this code into the \"Database Information\" \"Table prefix\" form field, or obtain sensitive information via a direct request for install/install.sql.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Code injection in n/a","id":"CVE-2018-14579","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"code_injection","year":"2018"},"n_packages":0,"n_references":1,"next":{"headline":"Code injection in n/a","id":"CVE-2018-14581"},"packages":[],"prev":{"headline":"Integer overflow in n/a","id":"CVE-2018-14576"},"products":["n/a"],"published":"2018-07-24","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-16","vendors":["n/a"]},"summary":"Attackers can execute arbitrary PHP code or read sensitive data if the install directory is left active after installation.","url":"https://insights.sbomify.com/CVE-2018-14579/"}